文献速递神经技术与安全CT

高能光子束全脑照射降低头皮剂量的剂量学研究

Dosimetric study of whole-brain irradiation with high-energy photon beams for dose reduction to the scalp.
PubMed 文献 · Br J Radiol · 2020-07-21

基于10例全脑照射患者的计划CT数据,比较6 MV与15 MV光子束联合或不联合野中野技术共4种计划的剂量分布。15 MV计划各头皮剂量参数均低于6 MV(p < 0.001),而脑表面最低剂量无显著差异,提示高能光子全脑照射可能在不妨碍脑表面剂量的前提下降低头皮剂量。

要点

  • 15 MV计划头皮各剂量参数均低于6 MV计划(p < 0.001)。
  • 联合野中野技术时,6 MV与15 MV脑表面最低剂量无显著差异(p = 0.70)。
  • 未联合野中野技术时,6 MV与15 MV脑表面最低剂量亦无显著差异(p = 0.66)。

诊断标准与关键数值

  • 联合野中野技术时,6 MV与15 MV光子束头皮平均剂量分别为24.4-26.0 Gy与22.4-24.1 Gy,最大剂量分别为30.5-32.1 Gy与28.5-30.8 Gy。
  • 未联合野中野技术时,6 MV与15 MV光子束头皮平均剂量分别为24.6-26.9 Gy与22.6-24.5 Gy,最大剂量分别为30.8-34.6 Gy与28.6-32.4 Gy。
  • 15 MV计划各头皮剂量参数均低于6 MV计划(p < 0.001)。
  • 联合野中野技术时,6 MV与15 MV计划脑表面最低剂量分别为28.9 ± 0.440 Gy与29.0 ± 0.557 Gy(p = 0.70)。
  • 未联合野中野技术时,6 MV与15 MV计划脑表面最低剂量分别为28.9 ± 0.456 Gy与29.0 ± 0.529 Gy(p = 0.66)。

临床应用与阅片要点

  • 作者认为高能光子全脑照射可能减轻接受全脑照射患者的脱发。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the efficiency of high-energy photons for mitigating alopecia due to whole-brain irradiation (WBRT).

METHODS: Planning CT data from 10 patients who received WBRT were collected. We prepared 4 WBRT plans that used 6 or 15 MV photon beams, with or without use of a field-in-field (FiF) technique, and compared outcomes using a treatment planning system. The primary outcome was dose parameters to the scalp, including the mean dose, maximum dose, and dose received to 50% scalp(D50%). Secondary outcomes were minimum dose to the brain surface.

RESULTS: Using FiF, the mean doses were 24.4-26.0 and 22.4-24.1 Gy, and the maximum doses were 30.5-32.1 and 28.5-30.8 Gy for 6 and 15 MV photon beams, respectively. Without FiF, the mean doses were 24.6-26.9 and 22.6-24.5 Gy, and the maximum doses were 30.8-34.6 and 28.6-32.4 Gy for 6 and 15 MV photon beams. The 15 MV plan resulted in a lower scalp dose for each dose parameter (p < 0.001). Using FiF, the minimum doses to the brain surface for the 6 and 15 MV plans were 28.9 ± 0.440 and 29.0 ± 0.557 Gy, respectively (p = 0.70). Without FiF, the minimum doses to the brain surface for the 6 and 15 MV plans were 28.9 ± 0.456 and 29.0 ± 0.529, respectively (p = 0.66).

CONCLUSION: Compared with the 6 MV plan, the 15 MV plan achieved a lower scalp dose without impairing the brain surface dose.

ADVANCES IN KNOWLEDGE: High-energy photon WBRT may mitigate alopecia of patients who receiving WBRT.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Sawada M, Kunieda E, Akiba T, et al. Dosimetric study of whole-brain irradiation with high-energy photon beams for dose reduction to the scalp. Br J Radiol. 2020. PMID: 32650647. doi:10.1259/bjr.20200159

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。