黑偶极子还是白偶极子:利用磁敏感相位成像鉴别脑微出血与颅内钙化
本研究回顾性纳入31例在梯度回波幅度图上显示暗点的急性梗死患者,由2名放射科医生分别评估暗点边缘和中心层面的相位模式及定量磁敏感图。190个梯度回波暗点中,CT检出62个钙化和128个脑微出血;边缘相位模式鉴别钙化的敏感度和特异度高于中心相位模式(98.4%和100% vs 79%和83.6%),与定量磁敏感图(100%和100%)相当。
要点
- 边缘相位模式鉴别钙化的敏感度和特异度分别为98.4%和100%,高于中心相位模式的79%和83.6%。
- 对于直径>2.5 mm的病灶,边缘相位模式鉴别钙化的敏感度和特异度均为100%,中心相位模式分别为66.7%和61.1%。
- 边缘相位模式的观察者间信度(κ=1)高于中心相位模式(κ=0.77,P<.05)。
关键影像表现/征象
- 在梯度回波幅度图上表现为暗点,边缘相位模式和中心相位模式可用于判断病灶的磁敏感性。
- 脑微出血和钙化的尺寸与磁敏感性高度相关,提示较大的病灶可能引起更大的相位变化。
诊断标准与关键数值
- 边缘相位模式鉴别钙化的敏感度为98.4%、特异度为100%,中心相位模式分别为79%和83.6%。
- 对于直径>2.5 mm的病灶,边缘相位模式鉴别钙化的敏感度和特异度均为100%,中心相位模式分别为66.7%和61.1%。
- 定量磁敏感图鉴别钙化的敏感度和特异度均为100%。
- 边缘相位模式的观察者间信度κ=1,中心相位模式κ=0.77(P<.05)。
临床应用与阅片要点
- 阅片时可优先观察暗点的边缘相位模式来鉴别钙化与脑微出血,其观察者间信度高于中心相位模式。
- 对于直径>2.5 mm的病灶,边缘相位模式的鉴别准确率更高。
- 边缘相位模式的鉴别准确率与定量磁敏感图相当。
局限性
- 本研究为回顾性研究。
- 仅6例患者有额外的定量磁敏感图图像。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Phase imaging helps determine a lesion's susceptibility. However, various inhomogenous phase patterns could be observed in the serial phase images of a lesion and render image interpretation challenging. We evaluated the diagnostic accuracy of differentiating cerebral microbleeds and calcifications from phase patterns in axial locations.
MATERIALS AND METHODS: This study retrospectively enrolled 31 consecutive patients undergoing both CT and MR imaging for acute infarction exhibiting dark spots in gradient-echo magnitude images. Six patients had additional quantitative susceptibility mapping images. To determine their susceptibility, 2 radiologists separately investigated the phase patterns in the border and central sections and quantitative susceptibility mapping of dark spots. Sensitivity and specificity were compared using the McNemar test. Interobserver reliability and correlation analysis were determined using the κ coefficient and Pearson correlation coefficient, respectively.
RESULTS: Among 190 gradient-echo dark spots, 62 calcifications and 128 cerebral microbleeds were detected from CT. Interobserver reliability was higher for the border phase patterns (κ = 1) than for the central phase patterns (κ = 0.77, P < .05). The sensitivity and specificity of the border phase patterns in identifying calcifications were higher than those of the central phase patterns (98.4% and 100% versus 79% and 83.6%), particularly for lesions >2.5 mm in diameter (100% and 100% versus 66.7% and 61.1%). The same values were obtained using quantitative susceptibility mapping for identification (100% and 100%). A high correlation between the size and susceptibility of cerebral microbleeds and calcifications suggested that greater phase changes may be caused by larger lesions.
CONCLUSIONS: The border phase patterns were more accurate than the central phase patterns in differentiating calcifications and cerebral microbleeds and was as accurate as quantitative susceptibility mapping.
引用
- Weng CL, Jeng Y, Li YT, et al. Black Dipole or White Dipole: Using Susceptibility Phase Imaging to Differentiate Cerebral Microbleeds from Intracranial Calcifications. AJNR Am J Neuroradiol. 2020. PMID: 32675335. doi:10.3174/ajnr.A6636