血管剪切波弹性成像在动脉粥样硬化动脉中的应用:系统综述
本系统综述纳入19项研究(10项人类患者、9项非人类受试者),评估超声剪切波弹性成像评估动脉粥样硬化动脉壁和斑块弹性的可行性及诊断价值。所有研究均显示该技术可行,但定量弹性值在研究间变异大;研究内可检测弹性差异并区分斑块类型,重复性良好。作者认为该技术可能有助于改善卒中风险分层,但需更多临床研究评估其确切临床价值。
要点
- 超声剪切波弹性成像可评估动脉壁和斑块的弹性,所有纳入研究均证实其可行性。
- 定量弹性值在研究间高度变异,但研究内可检测显著性弹性差异并区分斑块类型。
- 该技术可贯穿心动周期评估血管壁和斑块弹性,可能有助于改善卒中风险分层。
核心结论
- 超声剪切波弹性成像可评估动脉壁和斑块的弹性,所有纳入研究均显示可行。
- 研究间定量弹性值高度变异,但研究内可检测患者/受试者特征的显著性弹性差异,并以良好重复性区分不同斑块类型。
- 超声剪切波弹性成像可能有助于改善卒中风险分层,但需更多临床研究评估其确切临床价值。
研究设计与样本
- 系统综述,检索Pubmed、Embase、Web of Science和IEEE数据库,纳入19项研究,其中10项人类患者研究、9项非人类受试者研究(切除动物动脉和聚乙烯醇体模)。
- 采用QUADAS-2清单进行质量评估并提取相关数据。
诊断标准与关键数值
- 所有纳入研究均显示超声剪切波弹性成像可评估动脉壁和斑块的个体化硬度。
- 定量弹性值在研究间高度变异;研究内可检测患者/受试者特征的显著性弹性差异,并以良好重复性区分不同斑块类型。
临床应用与阅片要点
- 超声剪切波弹性成像具有贯穿心动周期评估血管壁和斑块弹性的独特能力,可能是改善卒中风险分层的候选技术。
- 作者指出需更多临床研究评估该技术的确切临床价值。
局限性
- 定量弹性值在研究间高度变异。
- 作者指出需更多临床研究评估该技术的确切临床价值。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Ischemic stroke is a leading cause of death and disability worldwide, so adequate prevention strategies are crucial. However, current stroke risk stratification is based on epidemiologic studies and is still suboptimal for individual patients. The aim of this systematic review was to provide a literature overview on the feasibility and diagnostic value of vascular shear wave elastography (SWE) using ultrasound (US) in (mimicked) human and non-human arteries affected by different stages of atherosclerotic diseases or diseases related to atherosclerosis. An online search was conducted on Pubmed, Embase, Web of Science and IEEE databases to identify studies using US SWE for the assessment of vascular elasticity. A quality assessment was performed using Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) checklist, and relevant data were extracted. A total of 19 studies were included: 10 with human patients and 9 with non-human subjects (i.e., [excised] animal arteries and polyvinyl alcohol phantoms). All studies revealed the feasibility of using US SWE to assess individually stiffness of the arterial wall and plaques. Quantitative elasticity values were highly variable between studies. However, within studies, SWE could detect statistically significant elasticity differences in patient/subject characteristics and could distinguish different plaque types with good reproducibility. US SWE, with its unique ability to assess the elasticity of the vessel wall and plaque throughout the cardiac cycle, might be a good candidate to improve stroke risk stratification. However, more clinical studies have to be performed to assess this technique's exact clinical value.
引用
- Pruijssen JT, de Korte CL, Voss I, et al. Vascular Shear Wave Elastography in Atherosclerotic Arteries: A Systematic Review. Ultrasound Med Biol. 2020. PMID: 32620385. doi:10.1016/j.ultrasmedbio.2020.05.013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。