文献速递腹部CT

第三代双源CT光谱滤过与先进模型迭代重建的CT结肠成像:图像质量、辐射剂量及临床实用性诊断效能

CT colonography with spectral filtration and advanced modeled iterative reconstruction in the third-generation dual-source CT: image quality, radiation dose and performance in clinical utility.
PubMed 文献 · Acad Radiol · 2020-05-17

125例筛查或诊断目的患者行CT结肠成像,仰卧位采用120kVp标准剂量(120kVp-STD)联合滤波反投影重建(FBP),俯卧位分别采用锡滤过150kVp低剂量(Sn150kVp-LD)和锡滤过100kVp超低剂量(Sn100kVp-ULD)联合ADMIRE重建。Sn150kVp-LD与Sn100kVp-ULD有效剂量较120kVp-STD分别降低22.5%和87.5%(1.55±0.30和0.25±0.07 mSv vs. 2.00±0.52 mSv,均p<0.01)。Sn150kVp-LD联合ADMIRE图像噪声和信噪比改善,与120kVp-STD主观图像质量及诊断效能相当;Sn100kVp-ULD联合ADMIRE主观图像质量下降,C-RADS结肠评分(C-score)无显著差异,但结肠外评分(E-score)有显著差异。

要点

  • Sn150kVp-LD联合ADMIRE有效剂量1.55±0.30 mSv,较120kVp-STD的2.00±0.52 mSv降低22.5%。
  • Sn150kVp-LD联合ADMIRE图像噪声和信噪比优于120kVp-STD,主观图像质量与诊断效能相当。
  • Sn100kVp-ULD联合ADMIRE有效剂量0.25±0.07 mSv,较120kVp-STD降低87.5%,但主观图像质量下降且C-RADS结肠外评分有显著差异。

核心结论

  • Sn150kVp与Sn100kVp联合ADMIRE重建可提供替代性低剂量CTC策略,在临床筛查或诊断场景中可能可行。

研究设计与样本

  • 共125例因筛查或诊断目的行CTC的患者,仰卧位采用120kVp标准剂量(120kVp-STD)联合滤波反投影重建(FBP),俯卧位分别采用锡滤过150kVp低剂量(Sn150kVp-LD)和锡滤过100kVp超低剂量(Sn100kVp-ULD)联合ADMIRE重建。
  • 记录辐射指标,比较客观与主观图像质量,并采用CTC报告和数据系统(C-RADS)评估结肠与结肠外病变的诊断效能。

关键影像表现/征象

  • Sn150kVp-LD联合ADMIRE较120kVp-STD图像噪声和信噪比显著改善,两者2D和3D主观图像质量均优且诊断效能相当。
  • Sn100kVp-ULD联合ADMIRE较120kVp-STD主观图像质量下降,C-RADS结肠外评分(E-score)有显著差异;C-RADS结肠评分(C-score)无显著差异。

诊断标准与关键数值

  • 采用CTC报告和数据系统(C-RADS)评估结肠与结肠外病变的诊断效能,结肠评分(C-score)与结肠外评分(E-score)分别评价。
  • Sn150kVp-LD与Sn100kVp-ULD有效剂量分别为1.55±0.30和0.25±0.07 mSv,120kVp-STD为2.00±0.52 mSv,前两者分别降低22.5%和87.5%(均p<0.01)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To evaluate image quality, radiation dose and its diagnostic performance in clinical utility of CT colonography (CTC) applying spectral filtration and advanced modeled iterative reconstruction (ADMIRE) techniques in third-generation dual-source CT.

MATERIALS AND METHODS: A total of 125 patients for screening or diagnostic purposes underwent CTC at 120kVp standard dose (120kVp-STD) with filtered-back projection reconstruction (FBP) in supine position, then at a tin-filtered 150 kVp low dose (Sn150kVp-LD) and a tin-filtered 100 kVp ultra-low dose (Sn100kVp-ULD) with ADMIRE reconstruction in prone position. Radiation metrics were recorded. Objective and subjective image qualities were compared, and the diagnostic performance was assessed for both colonic and extracolonic findings using CTC reporting and data system (C-RADS).

RESULTS: The effective dose was significantly lower for Sn150kVp-LD and Sn100kVp-ULD than 120kVp-STD protocol, resulting in 22.5% and 87.5% reductions (1.55±0.30 and 0.25±0.07 mSv vs. 2.00±0.52 mSv; both p<0.01), respectively. Image noise and signal-to-noise ratio were improved significantly for Sn150kVp-LD with ADMIRE compared with 120kVp-STD, both of which had similar excellent 2D and 3D subjective image quality with equivalent diagnostic performance. Sn100kVp-ULD with ADMIRE had decreased subjective image quality and significant different C-RADS extracolonic-score (E-score) compared with 120kVp-STD, however, C-RADS colonic-score (C-score) of that showed no significantly difference.

CONCLUSION: Sn150kVp and Sn100kVp with ADMIRE reconstruction provide an alternative low dose CTC strategy and could be feasible in clinical screening or diagnostic scenarios.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Liu JJ, Xue HD, Liu W, et al. CT colonography with spectral filtration and advanced modeled iterative reconstruction in the third-generation dual-source CT: image quality, radiation dose and performance in clinical utility. Acad Radiol. 2020. PMID: 32434689. doi:10.1016/j.acra.2020.03.040

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。