文献速递腹部儿科影像MR

评估儿童克罗恩病活动性:磁共振小肠造影整体评分(MEGS)与内镜活动性评分(SES-CD)对照验证

Assessment of pediatric Crohn's disease activity: validation of the magnetic resonance enterography global score (MEGS) against endoscopic activity score (SES-CD).
PubMed 文献 · Abdom Radiol (NY) · 2020-01-01

本研究纳入52例儿童克罗恩病患者,在7天内完成回结肠镜和磁共振小肠造影(MRE),于回肠末端获取SES-CD和MEGS评分。MEGS与SES-CD呈强相关(r=0.70,P<0.001),对回肠末端炎症检测的AUC为0.89(敏感度0.95、特异度0.82),对疾病活动性的AUC为0.81(敏感度0.88、特异度0.75)。作者认为MEGS是评估疾病活动性的有前景的方法。

要点

  • MEGS与SES-CD强相关(r=0.70,P<0.001),可用于评估儿童克罗恩病回肠末端炎症。
  • MEGS检测回肠末端炎症的AUC为0.89,敏感度0.95,特异度0.82。
  • MEGS诊断疾病活动性的AUC为0.81,敏感度0.88,特异度0.75。

关键影像表现/征象

  • 儿童克罗恩病患者上消化道受累发生率为23%,肛周病变发生率为42%,多数患者(86.5%)患有内痔。

诊断标准与关键数值

  • 以SES-CD为参考标准,MEGS检测回肠末端炎症的AUC为0.89,敏感度0.95,特异度0.82。
  • 以SES-CD为参考标准,MEGS诊断疾病活动性的AUC为0.81,敏感度0.88,特异度0.75。
  • MEGS与SES-CD的相关系数r=0.70(P<0.001)。

临床应用与阅片要点

  • 作者认为MEGS是评估疾病活动性的有前景的方法,并可能成为随访治疗变化的有价值工具。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The aim of this study is to evaluate the ability of magnetic resonance enterography global score (MEGS) to diagnose the activity of pediatric Crohn's disease (CD) and its correlation with endoscopic activity score.

MATERIALS AND METHODS: 70 pediatric CD patients (between the ages of 6 and 17) were enrolled who underwent ileocolonoscopy and magnetic resonance enterography (MRE) within 7 days. The simplified endoscopic activity score for Crohn's disease (SES-CD) and MEGS were acquired in the terminal ileum. Sensitivity and specificity of MEGS for detection disease activity against SES-CD was compared using the McNemar test. The correlation between MEGS and SES-CD was assessed by Spearman's rank estimation. The diagnostic accuracy of MEGS for active disease defined by SES-CD was calculated. Receiver operating characteristic curves (ROC) were constructed.

RESULTS: Fifty-two pediatric CD patients (median age, 12 years old; 28 girls, 24 boys) were included. The incidence of upper gastrointestinal (GI) tract (23%) involvement and perianal lesions (42%) is high in pediatric Crohn's patients, and most of them suffer from internal hemorrhoids (86.5%). MEGS showed strong correlation to SES-CD (r = 0.70, P < 0.001). With endoscopic as the standard of reference, the MEGS had a high accuracy for the detection of inflammation (area under the ROC curve (AUC) of 0.89, sensitivity 0.95 and specificity 0.82) and for disease activity (AUC of 0.81, sensitivity 0.88 and specificity 0.75) in the terminal ileum.

CONCLUSION: Pediatric Crohn's disease is unique. Our study has shown a good correlation between MEGS and endoscopy activity score with equal diagnostic efficacy. MEGS is a promising method to assess disease activity and perhaps be a valuable tool in following therapeutic changes.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Zheng X, Li M, Wu Y, et al. Assessment of pediatric Crohn's disease activity: validation of the magnetic resonance enterography global score (MEGS) against endoscopic activity score (SES-CD). Abdom Radiol (NY). 2020. PMID: 32458027. doi:10.1007/s00261-020-02590-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。