肠系膜内动态对比剂儿童MR淋巴管成像:初步经验及与结内和肝内MR淋巴管成像的比较
回顾性分析15例蛋白丢失性肠病和/或腹水患儿的肠系膜内、肝内及结内动态对比剂MR淋巴管成像,肠系膜内技术成功率为14/15(93%),在显示腹膜漏和十二指肠漏方面与结内成像存在显著差异,且无短期并发症,作者认为该技术可行但需进一步研究。
要点
- 肠系膜内动态对比剂MR淋巴管成像技术成功率达14/15(93%)。
- 肠系膜内成像可显示结内成像未见的腹膜漏和十二指肠漏。
- 该技术对肠系膜淋巴管异常的诊断和介入规划可能有帮助。
关键影像表现/征象
- 肠系膜内动态对比剂MR淋巴管成像在14/15(93%)的患者中成功完成。
- 与肠系膜内成像相比,结内成像在显示皮肤回流(p=0.014)、十二指肠灌注(p=0.003)、十二指肠漏(p=0.014)和腹膜漏(p=0.003)方面存在显著差异。
- 肠系膜内成像显示7例腹膜漏,肝内成像显示4例,结内成像未显示任何腹膜漏。
- 肝内成像显示9例十二指肠漏,肠系膜内成像显示5例,结内成像未显示任何十二指肠漏。
- 1例先天性蛋白丢失性肠病患者三种成像方式显示不同的离断血流模式,仅肠系膜内成像显示十二指肠漏。
临床应用与阅片要点
- 对于蛋白丢失性肠病和/或腹水患者,肠系膜内动态对比剂MR淋巴管成像可评估肠系膜淋巴管,可能有助于诊断和介入规划。
- 肠系膜内成像可显示结内成像未见的腹膜漏和十二指肠漏,阅片时需注意不同注射途径显示的淋巴漏部位存在差异。
- 操作无短期并发症。
局限性
- 原文结论指出该技术需进一步研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To report on our initial experience with intramesenteric (IM) dynamic contrast magnetic resonance lymphangiography (DCMRL) for evaluation of the lymphatics in patients with concern for mesenteric lymphatic flow disorders and to compare IM-DCMRL with intrahepatic (IH) and intranodal (IN) DCMRL.
METHODS: This is a retrospective review of imaging findings in 15 consecutive patients who presented with protein losing enteropathy (PLE) and/or ascites undergoing IM-DCMRL, IH-DCMRL, and IN-DCMRL. The IM-DCMRL technique involves the injection of a gadolinium contrast agent into the mesenteric lymphatic ducts or lymph nodes followed by imaging of the abdomen and chest with dynamic time-resolved MR lymphangiography.
RESULTS: IM-DCMRL was successfully performed in 14/15 (93%) of the patients. When comparing IN-DCMRL with IM-DCMRL, there was a significant difference in the visualization of dermal backflow (p = 0.014), duodenal perfusion (p = 0.003), duodenal leak (p = 0.014), and peritoneal leak (p = 0.003). IM-DCMRL demonstrated peritoneal leak in 7 patients in contrast to IH-DCMRL which demonstrated leak in 4 patients and IN-DCMRL which did not demonstrate any peritoneal leaks. Duodenal leaks were seen by IH-DCMRL in 9 patients versus 5 with IM-DCMRL and none with IN-DCMRL. In one patient with congenital PLE, the three modalities showed different disconnected flow patterns with duodenal leak only seen by IM-DCMRL. There were no short-term complications from the procedures.
CONCLUSIONS: IM-DCMRL is a feasible imaging technique for evaluation of the mesenteric lymphatics. In certain mesenteric lymphatic flow abnormalities, such as PLE and ascites, this imaging may be helpful for diagnosis and the planning of interventions and warrants further studies.
KEY POINTS: • Intramesenteric dynamic contrast magnetic resonance lymphangiography (IM-DCMRL) is a new imaging technique to evaluate mesenteric lymphatic flow disorders such as ascites. • IM-DCMRL is able to image lymphatic leaks in patients with ascites and protein losing enteropathy not seen with intranodal (IN-DCMRL) imaging.
引用
- Dori Y, Smith CL, DeWitt AG, et al. Intramesenteric dynamic contrast pediatric MR lymphangiography: initial experience and comparison with intranodal and intrahepatic MR lymphangiography. Eur Radiol. 2020. PMID: 32462442. doi:10.1007/s00330-020-06949-9