床旁超声测量的颈动脉血流时间与儿童血液透析患者容量变化相关
这项前瞻性观察研究在21例次儿童血液透析中获取168次床旁超声测量的颈动脉血流时间矫正值(CFTc),透析后CFTc降低21.7 ms(95%CI 12.3-31.0,p<0.001),透析前后CFTc变化与按体重校正的透析脱水量(mL/kg)呈比例相关(R2=0.224,p=0.03),被动抬腿试验前后CFTc无显著变化。
要点
- 儿童血透患者透析后CFTc较透析前降低21.7 ms(95%CI 12.3-31.0,p<0.001)。
- 透析前后CFTc变化与按体重校正的脱水量(mL/kg)相关(R2=0.224,p=0.03)。
- 被动抬腿试验前后平均CFTc无显著变化。
关键影像表现/征象
- 透析后CFTc较透析前降低21.7 ms(95%CI 12.3-31.0,p<0.001)。
- 透析前后CFTc变化与按体重校正的脱水量(mL/kg)呈比例相关(R2=0.224,p=0.03)。
- 被动抬腿试验前后平均CFTc无显著变化。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Carotid artery flow time corrected for heart rate (CFTc) correlates with intravascular volume changes in adults but has not been studied adequately in the pediatric population. We studied how fluid status changes correlate with CFTc in pediatric patients undergoing hemodialysis. This prospective observational study involved pediatric patients aged 5-18 y undergoing chronic hemodialysis at a tertiary care children's hospital in the United States. We measured CFTc by point-of-care ultrasound before and after each hemodialysis session, including passive leg raise. One hundred sixty-eight CFTc measurements were obtained from a total of 21 patient encounters. Post-dialysis CFTc decreased by 21.7 ms (95% confidence interval: 12.3-31.0) (p < 0.001). Pre- and post-dialysis ∆CFTc measurements were proportionally correlated with volume removed in dialysis adjusted for weight (mL/kg) (R2 = 0.224, p = 0.03). There was no significant change in mean CFTc with passive leg raise before or after hemodialysis. In children on hemodialysis, changes in CFTc were moderately correlated with decrease in intravascular volume after hemodialysis.
引用
- Patel AK, Mistry K, Breslin K, et al. Carotid Artery Flow Time Measured by Point-of-Care Ultrasound Correlates with Volume Changes in Pediatric Hemodialysis Patients. Ultrasound Med Biol. 2020. PMID: 32387153. doi:10.1016/j.ultrasmedbio.2020.03.034
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。