虚拟单能成像与投影基金属伪影减少方法联合用于全膝关节置换术后评估
本研究纳入36例有全膝关节置换术史患者的57个膝关节,比较无金属伪影减少、投影基金属伪影减少、虚拟单能成像及两者联合四种方案对金属伪影和图像质量的影响。联合方案在股骨区定量指标和软组织显示上表现最佳,投影基方案对骨结构显示最佳;胫骨区含虚拟单能成像的方案对比噪声比显著降低。
要点
- 联合虚拟单能成像与投影基金属伪影减少可进一步减少全膝关节置换术后CT金属伪影。
- 在金属伪影严重区域,联合方案对软组织显示最佳,投影基方案对骨结构显示最佳。
- 含虚拟单能成像的方案在胫骨区对比噪声比显著低于不含虚拟单能成像的方案。
核心结论
- 联合使用虚拟单能成像与投影基金属伪影减少方案的金属伪影减少表现优于单独使用投影基方案或虚拟单能成像。
- 在金属伪影严重区域,联合方案和投影基方案分别有助于软组织结构和骨结构的评估。
研究设计与样本
- 研究纳入36例有双侧或单侧全膝关节置换术史患者的57个膝关节。
- 比较无金属伪影减少、投影基金属伪影减少、虚拟单能成像及虚拟单能成像联合投影基金属伪影减少四种图像方案。
- 定量分析计算每种方案的面积、平均衰减、伪影指数和对比噪声比;定性分析采用相对视觉分级分析比较整体伪影及软组织和骨结构显示。
诊断标准与关键数值
- 在股骨区,联合方案在面积、平均衰减和伪影指数等定量指标上金属伪影减少表现最佳(p < .001)。
- 在胫骨区,含虚拟单能成像的金属伪影减少方案对比噪声比显著低于不含虚拟单能成像的方案(p < .001)。
- 定性分析中,联合方案的整体伪影少于其他两种金属伪影减少方案。
- 软组织在联合方案中显示最佳,骨结构在投影基方案中显示最佳(p < .001)。
临床应用与阅片要点
- 原文结论指出,在金属伪影严重区域,联合方案和投影基方案分别有助于软组织结构和骨结构的评估。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the effect of the combined use of virtual monochromatic imaging (VMI) and projection-based metal artifact reduction (PB-MAR) methods on further artifact reduction and image quality in total knee arthroplasty (TKA) patients.
METHODS: Fifty-seven knee joints from 36 patients who had a previous history of TKA for bilateral or unilateral knee joints were included in this study. Four sets of images were compared between non-MAR, PB-MAR, VMI, and VMI + PB-MAR. For quantitative analysis, the area, mean attenuation, artifact index (AI), and contrast-to-noise ratio (CNR) were calculated for each protocol. Regarding qualitative analysis, overall artifact and depiction of soft tissue and bony structure were compared using relative visual grading analysis.
RESULTS: In the femoral region, the VMI + PB-MAR protocol showed the best MAR performance in quantitative measures including area, mean attenuation, and AI (p < .001). However, MAR protocols with VMI showed significantly lower CNRs than did the protocols without VMI in the tibial region (p < .001). On qualitative analysis, VMI + PB-MAR also showed fewer overall artifacts than did the other two MAR protocols. Soft tissue was best depicted in VMI + PB-MAR protocol, and PB-MAR showed the best performance for the depiction of bony structure (p < .001).
CONCLUSIONS: The combined use of VMI and PB-MAR showed better MAR performance than did PB-MAR or VMI alone. In areas with severe metal artifacts, the VMI + PB-MAR and PB-MAR protocols were useful for the evaluation of soft tissue and bone structure, respectively.
KEY POINTS: • The combination of artifact reduction methods is effective in reducing metal artifacts in CT. • Soft tissue was best depicted in the combined protocol of projection- and dual-energy-based methods, and projection-based protocol showed the best performance for the depiction of bone structure in case of severe metal artifacts.
引用
- Chae HD, Hong SH, Shin M, et al. Combined use of virtual monochromatic images and projection-based metal artifact reduction methods in evaluation of total knee arthroplasty. Eur Radiol. 2020. PMID: 32424592. doi:10.1007/s00330-020-06932-4