文献速递骨肌MR

三角纤维软骨复合体(TFCC)创伤性损伤:应用高分辨率3-T MRI对Palmer分型的细化

Traumatic injury of the triangular fibrocartilage complex (TFCC)-a refinement to the Palmer classification by using high-resolution 3-T MRI.
PubMed 文献 · Skeletal Radiol · 2020-05-05

本研究回顾性纳入67例腕关节高分辨率3-T MRI检查患者,以关节镜或手术为标准,计算MRI诊断TFCC各型损伤的敏感度和特异度,并评估观察者间一致性。结果显示MRI对IA、IB、ID、复杂损伤及桶柄样撕裂的敏感度为67-100%、特异度为90-100%,观察者间一致性良好至完美(kappa 0.64-1.00),并发现囊膜损伤、关节盘水平撕裂及桶柄样撕裂等Palmer分型未涵盖的损伤模式,提示有必要细化经典Palmer分型。

要点

  • 高分辨率3-T MRI可识别Palmer分型未涵盖的TFCC损伤,如囊膜撕脱、关节盘水平撕裂和桶柄样撕裂。
  • MRI诊断TFCC各型损伤的敏感度为67-100%、特异度为90-100%,观察者间一致性良好至完美(kappa 0.64-1.00)。
  • 囊膜撕脱的诊断一致性较低(kappa 0.38),阅片时需注意。

核心结论

  • 高分辨率3-T MRI可发现更详细的TFCC损伤模式,包括囊膜损伤、关节盘水平撕裂和桶柄样撕裂,有必要细化经典Palmer分型。

研究设计与样本

  • 回顾性研究,2015年11月至2019年5月纳入67例符合入选和排除标准的患者,均行腕关节高分辨率3-T MRI,其中11例行间接MR关节造影。
  • 所有MRI由两名经验丰富的肌骨放射科医生阅片,以关节镜和手术为标准参考计算诊断敏感度、特异度和准确率,采用kappa分析评估观察者间一致性。

关键影像表现/征象

  • 关节镜或手术 confirmed 的49例TFCC损伤中,32例为原始Palmer损伤(IA=10、IB=19、ID=3),5例为囊膜撕脱,4例为罕有报道的TFCC桶柄样撕裂,8例为涉及上述分类的复杂损伤。
  • MRI对IA、IB、ID、复杂损伤和桶柄样撕裂的诊断敏感度为67-100%、特异度为90-100%,观察者间一致性良好至完美(kappa 0.64-1.00)。
  • 囊膜撕脱的诊断效能较低(kappa 0.38)。

诊断标准与关键数值

  • 以关节镜和手术为标准参考,MRI诊断IA、IB、ID、复杂损伤和桶柄样撕裂的敏感度为67-100%、特异度为90-100%。
  • 观察者间一致性kappa值为0.64-1.00(良好至完美),囊膜撕脱的kappa值为0.38。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The aim of this study was to investigate the MR features of the traumatic injury of the triangular fibrocartilage complex (TFCC) by using high-resolution 3-T magnetic resonance imaging (MRI) and to refine the Palmer classification system.

MATERIALS AND METHODS: From November 2015 to May 2019, sixty-seven patients met the including and excluding criteria and were enrolled into this retrospective study. All subjects had high-resolution 3-T MRI scan of the wrist and eleven had indirect MR arthrography of the wrist. All the MRI were read by two experienced musculoskeletal radiologists. Diagnostic sensitivity, specificity, and accuracy of MRI were calculated by using the arthroscopy and surgery as the standard of reference. A P value less than 0.05 was considered statistically significant. The interobserver agreement was assessed by kappa analysis.

RESULTS: There were 49 cases of TFCC injuries proven by the arthroscopy or surgery. The TFCC injuries in the other 18 patients were proved by the combination of clinical follow-up examination and follow-up MRI. Among the arthroscopy- or surgery-confirmed cases, there were 32 patients with original Palmer injuries (IA = 10, IB = 19, ID = 3), 5 with capsular detachment, 4 with bucket-handle tear of the TFCC that have rarely been reported, and 8 with complex injuries that involved the listed classifications above. The sensitivities and specificities of MRI for diagnosing IA, IB, ID, complex injuries, and bucket-handle tear were 67-100% and 90-100%, and overall good to perfect interobserver agreements (kappa, 0.64-1.00). The diagnostic performance for the capsular detachment was lower (kappa, 0.38).

CONCLUSION: With high-resolution 3-T MRI, more detailed injury patterns were found including capsular injuries, the horizontal tear of the articular disk, and the bucket-handle tear. It is necessary to refine the classic Palmer classification of TFCC injuries.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Zhan H, Bai R, Qian Z, et al. Traumatic injury of the triangular fibrocartilage complex (TFCC)-a refinement to the Palmer classification by using high-resolution 3-T MRI. Skeletal Radiol. 2020. PMID: 32372253. doi:10.1007/s00256-020-03438-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。