双能量能谱CT成像提高下肢动脉诊断准确率
回顾性比较110例双能量能谱CT(DEsCT)与72例常规100kVp下肢CTA,DEsCT组重建50keV单能量图像。以DSA为金标准,50keV图像在膝下段动脉的强化、SNR、CNR及主观图像质量均优于常规组,对膝下段动脉50%狭窄和闭塞的诊断准确率也更高。
要点
- 双能量能谱CT的50keV单能量图像可提高膝下段动脉的强化程度和图像质量。
- 以DSA为金标准,50keV图像对膝下段动脉50%狭窄和闭塞的诊断准确率高于常规100kVp CTA。
- 阅片时膝下段动脉狭窄评估可优先参考50keV单能量图像。
关键影像表现/征象
- DEsCT组50keV图像膝下段动脉强化程度为544.91±106.37HU,常规100kVp组为339.65±83.74HU(P<0.001)。
- DEsCT组50keV图像SNR为19.92±9.39,常规100kVp组为17.39±4.99(P=0.04)。
- DEsCT组50keV图像CNR为45.60±16.61,常规100kVp组为38.70±18.17(P<0.01)。
- Mann-Whitney检验显示DEsCT组膝下段动脉主观图像质量高于常规组(P=0.01)。
诊断标准与关键数值
- 以DSA为金标准,DEsCT组对膝下段动脉50%狭窄的诊断准确率为95.91%,常规组为87.85%(P<0.001)。
- 以DSA为金标准,DEsCT组对膝下段动脉闭塞的诊断准确率为94.32%,常规组为89.58%(P=0.02)。
临床应用与阅片要点
- 采用双能量能谱CT行下肢CTA时,重建50keV单能量图像可提高膝下段动脉的强化和图像质量。
- 评估膝下段动脉狭窄程度时,50keV图像对50%狭窄和闭塞的诊断准确率高于常规100kVp图像。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Investigate the clinical value of improving diagnostic accuracy for arteries of lower extremities with low energy images in dual-energy spectral CT (DEsCT) imaging.
METHOD: 110 (mean age, 67 ± 10 years) and 72 (mean age, 65 ± 13 years) patients underwent CT angiography (CTA) in the lower extremities using dual-energy and conventional (100kVp) imaging mode, retrospectively. The 50 keV monochromatic images were reconstructed in the DEsCT group for analysis. The quantitative and qualitative image quality of the two groups were compared using various statistical analysis methods and the diagnostic accuracy for the degree of vessel stenosis was compared using DSA as the gold standard. Consistency test was used for intra-group evaluation. A P < 0.05 was considered statistically significant.
RESULTS: The use of 50 keV images in DEsCT significantly increased the enhancement in arteries of LKS (544.91 ± 106.37HU vs. 339.65 ± 83.74HU, P < 0.001) and provided higher SNR (19.92±9.39 vs. 17.39±4.99, P = 0.04) and CNR (45.60±16.61 vs. 38.70±18.17, P < 0.01) compared with conventional 100kVp images. Mann-Whitney test showed that the subjective image quality of the arteries of lower knee segment (LKS) in the DEsCT group was higher than in the conventional group (P = 0.01). The diagnostic efficiency of DEsCT group was better than that of conventional group, mainly in arteries of LKS (95.91 % vs. 87.85 %, for 50 % stenosis, P<0.001; 94.32 % vs. 89.58 % for occlusion, P = 0.02).
CONCLUSIONS: The use of 50 keV DEsCT images enhances the contrast in the lower extremity arteries and improves the diagnostic accuracy for the arteries of LKS, compared with the conventional CTA protocols.
引用
- Jia X, Li X, Li J, et al. Improving diagnostic accuracy for arteries of lower extremities with dual-energy spectral CT imaging. Eur J Radiol. 2020. PMID: 32442836. doi:10.1016/j.ejrad.2020.109061
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。