文献速递骨肌MR

临床与半定量软骨分级系统预测关节镜下半月板部分切除术后结局的比较

Comparison of Clinical and Semiquantitative Cartilage Grading Systems in Predicting Outcomes After Arthroscopic Partial Meniscectomy.
PubMed 文献 · AJR Am J Roentgenol · 2020-05-06

本研究纳入78例术前6个月内行膝关节MRI并接受关节镜下半月板部分切除术的患者,由两名放射科医生和一名放射学研究员用改良Outerbridge临床分级与MRI骨关节炎膝关节评分半定量系统评估软骨缺失。临床分级预测手术成败的AUC为0.695(95%CI 0.566-0.824),非劣于MRI骨关节炎膝关节评分(AUC=0.683,95%CI 0.539-0.827,p=0.047);两者均优于仅用人口学特征的模型(AUC=0.667,95%CI 0.522-0.812)。临床分级读者间一致率80.8%,高于MRI骨关节炎膝关节评分的65.0%(p=0.012)。

要点

  • 临床改良Outerbridge分级预测半月板部分切除术后结局非劣于半定量MRI骨关节炎膝关节评分。
  • 临床分级读者间一致率80.8%,高于半定量评分的65.0%(p=0.012)。
  • 两种MRI模型预测能力均优于仅用人口学特征的模型(AUC 0.667)。

核心结论

  • 临床使用的软骨缺失MRI分级系统在预测关节镜下半月板部分切除术后结局方面与半定量系统效果相当,且读者间一致率更高。

研究设计与样本

  • 研究纳入术前6个月内行膝关节MRI、且有手术时及术后1年结局数据的患者共78例(女38例、男40例,平均年龄56.6岁)。
  • 由两名放射科医生和一名放射学研究员分别使用临床改良Outerbridge系统和MRI骨关节炎膝关节评分半定量系统评估软骨缺失。
  • 采用ROC曲线下面积(AUC)及95%CI评估各系统区分手术成功与失败的准确性,Wald检验评估临床分级系统的非劣效性,并比较读者间一致率。

诊断标准与关键数值

  • 临床分级预测模型AUC=0.695(95%CI 0.566-0.824),非劣效性检验p=0.047。
  • MRI骨关节炎膝关节评分预测模型AUC=0.683(95%CI 0.539-0.827)。
  • 仅用人口学特征的模型AUC=0.667(95%CI 0.522-0.812)。
  • 临床分级读者间一致率80.8%,MRI骨关节炎膝关节评分读者间一致率65.0%(p=0.012)。

临床应用与阅片要点

  • 临床改良Outerbridge分级可用于术前膝关节MRI软骨缺失评估,以预测半月板部分切除术后结局。
  • 该临床分级系统读者间一致率高于半定量MRI骨关节炎膝关节评分,可能有利于日常报告的一致性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE. Cartilage loss on preoperative knee MRI is a predictor of poor outcomes after arthroscopic partial meniscectomy. The purpose of this study was to compare the ability to predict outcomes after arthroscopic partial meniscectomy with a clinically used modified Outerbridge system versus a semiquantitative MRI Osteoarthritis Knee Score system for grading cartilage loss. MATERIALS AND METHODS. Patients who underwent preoperative knee MRI within 6 months of arthroscopic partial meniscectomy and who had outcomes available from the time of surgery and 1 year later were eligible for inclusion. Cases were evaluated by two radiologists and one radiology fellow with the use of both grading systems. The accuracy of each system in discriminating between surgical success and failure was estimated using the ROC curve (AUC) with 95% CIs. A Wald test was used to assess noninferiority of the clinical grading system. Interreader agreement regarding the accuracy of the grading systems in predicting outcomes was also compared. RESULTS. A total of 78 patients (38 women and 40 men; mean age, 56.6 years) were included in the study. A prediction model using clinical grading (AUC = 0.695; 95% CI, 0.566-0.824) was noninferior (p = 0.047) to a model using MRI Osteoarthritis Knee Score grading (AUC = 0.683; 95% CI, 0.539-0.827). Both MRI prediction models performed better than a model using demographic characteristics only (AUC = 0.667; 95% CI, 0.522-0.812). Inter-reader agreement with clinical grading (80.8%) was higher than that with MRI Osteoarthritis Knee Score grading (65.0%; p = 0.012). CONCLUSION. A clinically used system to grade cartilage loss on MRI is as effective as a semiquantitative system for predicting outcomes after arthroscopic partial meniscectomy, while also offering improved interreader agreement.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Colak C, Polster JM, Obuchowski NA, et al. Comparison of Clinical and Semiquantitative Cartilage Grading Systems in Predicting Outcomes After Arthroscopic Partial Meniscectomy. AJR Am J Roentgenol. 2020. PMID: 32374669. doi:10.2214/AJR.19.22285

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。