文献速递骨肌技术与安全MR

基于腰椎磁共振成像的影像组学检测骨质疏松

Radiomics Based on Lumbar Spine Magnetic Resonance Imaging to Detect Osteoporosis.
PubMed 文献 · Acad Radiol · 2020-05-06

本研究纳入109例同时接受双能X线吸收测定和腰椎MRI的患者,提取T1WI和T2WI影像组学特征建立分类模型,用于区分正常与骨量减少、正常与骨质疏松、骨量减少与骨质疏松。基于T1WI+T2WI的模型AUC分别为0.810、0.797和0.769。结论认为基于腰椎MRI的影像组学模型可用于检测骨质疏松。

要点

  • 基于T1WI+T2WI的影像组学模型在区分正常与骨量减少、正常与骨质疏松、骨量减少与骨质疏松时AUC分别为0.810、0.797、0.769。
  • 单独T1WI或T2WI模型的AUC较低,联合T1WI+T2WI模型对正常与骨质疏松的区分AUC达0.797。
  • 影像组学模型有望辅助腰椎MRI检测骨质疏松,但原文未报告敏感度、特异度及诊断阈值。

关键影像表现/征象

  • 腰椎MRI信号强度与骨密度相关,本研究基于T1WI和T2WI图像提取影像组学特征。
  • 从T1WI和T2WI分割图像中共提取396×2个影像组学特征,筛选后建立分类模型。

诊断标准与关键数值

  • 正常与骨量减少模型:基于T1WI、T2WI、T1WI+T2WI的AUC分别为0.772、0.772、0.810。
  • 正常与骨质疏松模型:基于T1WI、T2WI、T1WI+T2WI的AUC分别为0.724、0.682、0.797。
  • 骨量减少与骨质疏松模型:基于T1WI、T2WI、T1WI+T2WI的AUC分别为0.730、0.734、0.769。

临床应用与阅片要点

  • 原文结论认为基于腰椎MRI的影像组学模型可用于检测骨质疏松,未给出具体阅片或报告建议。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Signal intensity of the lumbar spine in magnetic resonance imaging (MRI) correlates to bone mineral density (BMD). This study aims to explore a lumbar spine magnetic resonance imaging based on the radiomics model for detecting osteoporosis.

MATERIALS AND METHODS: A total of 109 patients, who underwent both dual-energy X-ray absorptiometry (DEXA) and MRI of the lumbar spine, were recruited. Among these patients, 38 patients were normal, 32 patients had osteopenia, and 39 patients had osteoporosis, according to the DEXA results. A total of 396 × 2 radiomic features were extracted from the T1WI and T2WI images of the segmentation images in the lumbar magnetic resonance imaging. The correlated radiomic features were selected to establish the radiomic classification model. Then, the classification models (based on T1WI, T2WI, and T1WI+T2WI) of normal vs. osteopenia, normal vs. osteoporosis, and osteopenia vs. osteoporosis were established. The performance of the classification models was evaluated through the estimated area under the receiver operating characteristic curve.

RESULTS: The area under the receiver operating characteristic curves based on T1WI, T2WI, and T1WI+T2WI were 0.772, 0.772, and 0.810, respectively, for the models of normal vs. osteopenia, 0.724, 0.682, and 0.797, respectively, for the models of normal vs. osteoporosis, and 0.730, 0.734, and 0.769, respectively, for the models of osteopenia vs. osteoporosis.

CONCLUSION: Radiomic models established based on lumbar spine MRI can be used to detect osteoporosis.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. He L, Liu Z, Liu C, et al. Radiomics Based on Lumbar Spine Magnetic Resonance Imaging to Detect Osteoporosis. Acad Radiol. 2020. PMID: 32386949. doi:10.1016/j.acra.2020.03.046

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。