文献速递骨肌US

超声成像可可靠测量胫骨后肌尺寸

Ultrasound Imaging Is Reliable for Tibialis Posterior Size Measurements.
PubMed 文献 · J Ultrasound Med · 2020-05-15

研究纳入23名健康志愿者,在胫骨长度30%和50%处的前、后视图共4个位置测量胫骨后肌横截面积和厚度,组内相关系数0.988-0.998,信度优秀;作者推荐在胫骨长度30%处前视图测量横截面积。

要点

  • 胫骨后肌横截面积和厚度在4个位置测量均显示优秀信度(ICC 0.988-0.998)。
  • 30%位置的测量误差(LoA、SEM)略低于50%位置。
  • 作者推荐在胫骨长度30%处前视图测量横截面积,因其采集便捷且数据质量好。

关键影像表现/征象

  • 胫骨后肌横截面积和厚度在所有测量位置的组内相关系数为0.988-0.998,信度优秀。
  • 30%位置的LoA为4.6-9.2、SEM为0.03-0.05,50%位置的LoA为6.4-9.7、SEM为0.04-0.07,30%位置略低。
  • 横截面积前、后视图测量强相关:30%处r=0.99(P<.0001),50%处r=0.94(P<.0001)。
  • 厚度前、后视图测量强相关:30%处r=0.98(P<.0001),50%处r=0.95(P=.0001)。

诊断标准与关键数值

  • 信度以组内相关系数评估,横截面积和厚度在所有位置为0.988-0.998。
  • 测量误差以LoA和SEM评估:30%位置LoA 4.6-9.2、SEM 0.03-0.05;50%位置LoA 6.4-9.7、SEM 0.04-0.07。
  • 前、后视图相关性:横截面积30%处r=0.99(P<.0001)、50%处r=0.94(P<.0001);厚度30%处r=0.98(P<.0001)、50%处r=0.95(P=.0001)。

临床应用与阅片要点

  • 作者推荐在胫骨长度30%处前视图测量胫骨后肌横截面积,因采集便捷且数据质量好。
  • 作者认为超声可在所测试的任何位置准确测量胫骨后肌。
  • 作者认为评估胫骨后肌肌肉大小将有助于多种医学和研究应用。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The tibialis posterior (TP) is a vital muscle for controlling the medial longitudinal arch of the foot during weight-bearing activities. Dysfunction of this muscle is associated with a variety of pathologic conditions; thus, it is important to reliably assess its morphologic characteristics. Ultrasound (US) has been used to assess characteristics of TP tendons but not the muscle cross-sectional area (CSA). The purpose of this study was to establish a reliable US technique to measure the TP CSA and thickness.

METHODS: Twenty-three healthy volunteers participated. We evaluated the CSA and thickness at 4 measurement locations (anterior and posterior views at both 30% and 50% of the shank length).

RESULTS: The participants included 12 female and 11 male volunteers (mean age ± SD, 31.23 ± 14.93 years). Excellent reliability was seen for the CSA and thickness at all locations (intraclass correlation coefficients, 0.988-0.998). Limits of agreement (LoA) and standard errors of the measurement (SEMs) were slightly lower at the 30% locations (LoA at 30%, 4.6-9.2; LoA at 50%, 6.4-9.7; SEM at 30%, 0.03-0.05; SEM at 50%, 0.04-0.07). Strong correlations were seen between anterior and posterior measurements of the CSA (30%, r = 0.99; P < .0001; 50%, r = 0.94; P < .0001) and thickness (30%, r = 0.98; P < .0001; 50%, r = 0.95; P = .0001).

CONCLUSIONS: Based on these results, the TP can be measured accurately with US at any of the tested locations. Due to the ease of collection and the quality of the data, we recommend the anterior view at 30% of the shank length to measure the CSA. The ability to assess muscle size of the TP will aid in a variety of medical and research applications.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Johnson AW, Bruening DA, Violette VA, et al. Ultrasound Imaging Is Reliable for Tibialis Posterior Size Measurements. J Ultrasound Med. 2020. PMID: 32412115. doi:10.1002/jum.15340

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。