文献速递乳腺MR

多b值扩散加权成像鉴别乳腺良恶性病变:常规单指数、双指数与拉伸指数模型的比较

Multiple b-value diffusion-weighted imaging in differentiating benign from malignant breast lesions: comparison of conventional mono-, bi- and stretched exponential models.
PubMed 文献 · Clin Radiol · 2020-05-08

前瞻性纳入103例患者行3T MRI,比较单b值DWI与多b值DWI(12个b值,0–3,000 s/mm²)衍生的ADC、D、f、D*、DDC和α参数在乳腺良恶性病变鉴别中的价值。各参数观察者间与观察者内一致性良好,D、D*、f、DDC和α在恶性肿瘤、良性病变与正常乳腺组织间差异有统计学意义(p<0.05)。结论认为D、f、DDC、α和ADC值分别具有较好的敏感度和特异度,D与f或DDC与α联合使用诊断效能良好,多b值DWI新变量或联合变量应用前景可期。

要点

  • 多b值DWI可同时获得ADC、D、f、D*、DDC和α等参数,各参数重复测量一致性良好。
  • D、D*、f、DDC和α值在恶性肿瘤、良性病变与正常乳腺组织间差异有统计学意义(p<0.05)。
  • D与f联合或DDC与α联合使用具有良好诊断效能。

核心结论

  • D、f、DDC、α和ADC值分别具有较好的敏感度和特异度。
  • D与f联合或DDC与α联合使用具有良好诊断效能,多b值DWI新变量或联合变量应用前景可期。

研究设计与样本

  • 前瞻性研究,纳入103例患者,行3T MRI检查。
  • 常规序列包括T1加权动态增强、T1加权与T2加权脂肪抑制序列、单b值(b=0、1000 s/mm²)DWI及多b值(12个b值,0–3,000 s/mm²)DWI。
  • 病理诊断依据最新世界卫生组织(WHO)乳腺病理与免疫组化指南。
  • 由同一名放射科医师间隔3个月重复测量两次,计算ADC、组织扩散系数(D)、灌注分数(f)、伪扩散系数(D*)、分布扩散系数(DDC)和α。
  • 统计学分析使用SPSS Statistics V19.0。

诊断标准与关键数值

  • D、D*、f、DDC和α值在恶性肿瘤、良性病变与正常乳腺组织间差异有统计学意义(p<0.05)。
  • 各参数观察者间与观察者内一致性良好。
  • D、f、DDC、α和ADC值分别具有较好的敏感度和特异度。
  • D与f联合或DDC与α联合使用具有良好诊断效能。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To prospectively evaluate multiple b-value diffusion-weighted imaging (DWI) in differentiating malignant from benign breast lesions.

MATERIALS AND METHODS: The study cohort included 103 patients who underwent 3 T magnetic resonance imaging (MRI). The conventional sequences included T1-weighted dynamic contrast-enhanced, T1-weighted and T2-weighted fat-suppressed sequences, single b-value (b=0, 1000 s/mm2) DWI, and multiple b-values (12 values, from 0 to 3,000 s/mm2) DWI. Pathological diagnosis of breast lesions was based on the latest World Health Organization (WHO) guide on the pathology and immunohistochemistry of the breast. SPSS Statistics V19.0 was used for the statistics analysis.

RESULTS: The following parameters were calculated: apparent diffusion coefficient (ADC), tissue diffusivity (D), perfusion fraction (f), pseudo-diffusion coefficient (D∗), distributed diffusion coefficient (DDC), and alpha (α) by the same radiologist twice (interval time of 3 months). There was good inter/intra-observer agreement for each of the parameters. The D, D∗, f, DDC, and α values were significantly different among malignant tumours, benign lesions, and normal breast tissue (p<0.05).

CONCLUSION: D, f, DDC, α, and ADC values have good sensitivity and specificity, respectively. In addition, the combined use of D and f or DDC and α has good diagnostic performance. Thus, the applications of the new multi-b DWI variables or combined variables are promising.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Chen BY, Xie Z, Nie P, et al. Multiple b-value diffusion-weighted imaging in differentiating benign from malignant breast lesions: comparison of conventional mono-, bi- and stretched exponential models. Clin Radiol. 2020. PMID: 32389372. doi:10.1016/j.crad.2020.03.039

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。