文献速递乳腺乳腺X线

基于乳腺X线摄影的影像组学列线图:预测乳腺癌腋窝淋巴结转移的潜在生物标志物

Mammography-based radiomics nomogram: a potential biomarker to predict axillary lymph node metastasis in breast cancer.
PubMed 文献 · Br J Radiol · 2020-05-27

本研究纳入216例经手术病理证实的乳腺癌患者,从乳腺X线摄影头尾位图像提取影像组学特征,结合孕激素受体状态和分子分型构建列线图,用于术前预测腋窝淋巴结转移。列线图在主队列和验证队列的AUC分别为0.883和0.863,优于单独临床特征和影像组学特征,作者认为可作为无创工具辅助术前决策。

要点

  • 基于乳腺X线摄影的影像组学列线图预测腋窝淋巴结转移的主队列AUC为0.883,验证队列为0.863。
  • 列线图包含孕激素受体状态、分子分型和影像组学特征,校准曲线显示良好校准。
  • 乳腺X线摄影报告标准诊断腋窝淋巴结转移的敏感度仅42.7%,特异度90.8%,AUC为0.666。

核心结论

  • 基于乳腺X线摄影的影像组学列线图可作为无创且可靠的工具预测腋窝淋巴结转移,可能有助于辅助临床医生术前决策。

研究设计与样本

  • 研究为影像组学研究,纳入216例经手术切除病理证实的乳腺癌病灶患者,分为主队列144例和验证队列72例。
  • 从乳腺X线摄影头尾位图像提取影像组学特征,采用方差分析F值和最小绝对收缩与选择算子进行特征选择,支持向量机方法构建影像组学特征。
  • 采用多变量逻辑回归分析建立结合影像组学特征和临床因素的列线图,在主队列和验证队列中基于回归分析得出C指数和校准曲线。

诊断标准与关键数值

  • 216例中95例经病理证实腋窝淋巴结转移,52例基于乳腺X线摄影报告标准诊断为腋窝淋巴结转移。
  • 乳腺X线摄影报告标准的敏感度42.7%、特异度90.8%、准确率24.1%,AUC为0.666(95%CI:0.591-0.741)。
  • 影像组学列线图在主队列AUC为0.883,验证队列AUC为0.863。
  • 单独临床特征在主队列AUC为0.707,验证队列AUC为0.657;单独影像组学特征在主队列AUC为0.876,验证队列AUC为0.862。

临床应用与阅片要点

  • 列线图整合孕激素受体状态、分子分型和影像组学特征,可用于术前无创预测腋窝淋巴结转移。
  • 乳腺X线摄影报告标准对腋窝淋巴结转移检测价值有限,敏感度42.7%、准确率24.1%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To establish a radiomics nomogram by integrating clinical risk factors and radiomics features extracted from digital mammography (MG) images for pre-operative prediction of axillary lymph node (ALN) metastasis in breast cancer.

METHODS: 216 patients with breast cancer lesions confirmed by surgical excision pathology were divided into the primary cohort (n = 144) and validation cohort (n = 72). Radiomics features were extracted from craniocaudal (CC) view of mammograms, and radiomics features selection were performed using the methods of ANOVA F-value and least absolute shrinkage and selection operator; then a radiomics signature was constructed with the method of support vector machine. Multivariate logistic regression analysis was used to establish a radiomics nomogram based on the combination of radiomics signature and clinical factors. The C-index and calibration curves were derived based on the regression analysis both in the primary and validation cohorts.

RESULTS: 95 of 216 patients were confirmed with ALN metastasis by pathology, and 52 cases were diagnosed as ALN metastasis based on MG-reported criteria. The sensitivity, specificity, accuracy and AUC (area under the receiver operating characteristic curve of MG-reported criteria were 42.7%, 90.8%, 24.1% and 0.666 (95% confidence interval: 0.591-0.741]. The radiomics nomogram, comprising progesterone receptor status, molecular subtype and radiomics signature, showed good calibration and better favorite performance for the metastatic ALN detection (AUC 0.883 and 0.863 in the primary and validation cohorts) than each independent clinical features (AUC 0.707 and 0.657 in the primary and validation cohorts) and radiomics signature (AUC 0.876 and 0.862 in the primary and validation cohorts).

CONCLUSION: The MG-based radiomics nomogram could be used as a non-invasive and reliable tool in predicting ALN metastasis and may facilitate to assist clinicians for pre-operative decision-making.

ADVANCES IN KNOWLEDGE: ALN status remains among the most important breast cancer prognostic factors and is essential for making treatment decisions. However, the value of detecting metastatic ALN by MG is very limited. The studies on pre-operative ALN metastasis prediction using the method of MG-based radiomics in breast cancer are very few. Therefore, we studied whether MG-based radiomics nomogram could be used as a predictive biomarker for the detection of metastatic ALN.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Tan H, Wu Y, Bao F, et al. Mammography-based radiomics nomogram: a potential biomarker to predict axillary lymph node metastasis in breast cancer. Br J Radiol. 2020. PMID: 32401540. doi:10.1259/bjr.20191019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。