附件肿块磁共振评分系统:弥散加权成像及表观弥散系数图附加价值的前瞻性验证
前瞻性纳入2015年1月至2018年9月323例经阴道超声诊断附件肿块的连续女性,行标准化MRI(含弥散及动态增强序列),其中131例后续手术。以组织学为金标准,比较经典ADNEX MR评分与纳入DWI及ADC图的改良评分,改良评分AUC更高(0.974 vs 0.938,P=0.0032),特异性提高。
要点
- 改良ADNEX MR评分将DWI及ADC图纳入,诊断恶性AUC由0.938升至0.974。
- 评分≥4分诊断恶性:改良评分特异性93.3%,高于经典评分86.6%。
- DWI及ADC图可整合入ADNEX MR评分系统以提高特异性。
关键影像表现/征象
- MRI检出全部161个附件肿块,组织学证实恶性组47个(32个恶性肿瘤及15个交界性肿瘤),良性病变114个。
诊断标准与关键数值
- 经典ADNEX MR评分系统预测恶性AUC为0.938(95%CI 0.902-0.975),改良评分系统AUC为0.974(95%CI 0.953-0.996),两者比较P=0.0032。
- 经典评分系统ADNEX MR评分≥4分诊断恶性的敏感度为95.5%、特异度为86.6%。
- 改良评分系统ADNEX MR评分≥4分诊断恶性的敏感度为95.7%、特异度为93.3%。
临床应用与阅片要点
- 阅片及报告附件肿块时可应用ADNEX MR评分系统,并纳入DWI及ADC图进行改良评分。
- 评分≥4分提示恶性,改良评分较经典评分特异性更高。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To validate prospectively the ADNEX magnetic resonance (MR) scoring system to assess adnexal masses and to evaluate a new, modified ADNEX MR scoring system that incorporates diffusion-weighted imaging (DWI) with apparent diffusion coefficient (ADC) mapping.
METHODS: Between January 2015 and September 2018, 323 consecutive women with adnexal masses diagnosed on transvaginal ultrasound (TVS) underwent standardized MR imaging (MRI) including diffusion and dynamic contrast-enhanced sequences. Of these, 131 underwent subsequent surgery. For interpretation of the MRI examinations, we applied the five-category ADNEX MR scoring system, along with a modified scoring system including DWI with ADC mapping. For both scoring systems, a score was given for all adnexal masses. Histological diagnosis was considered as the gold standard and lesions were classified as benign or malignant. The difference between the predictive values for diagnosing malignancy of the classical and modified scoring systems was assessed on the basis of the areas under the receiver-operating-characteristics (AUC) curves. The sensitivity and specificity for diagnosing malignancy of each score were also calculated.
RESULTS: Among the 131 women with adnexal mass(es) diagnosed on TVS who underwent MRI and subsequent surgery, the surgery revealed 161 adnexal masses in 126 women; five women had no mass. Histological examination confirmed 161 adnexal masses, of which all had been detected on MRI: 32 malignant tumors, 15 borderline tumors, which were classified as part of the malignant group (n = 47), and 114 benign lesions. The AUC for prediction of a malignant lesion was 0.938 (95% CI, 0.902-0.975) using the classical ADNEX MR scoring system and 0.974 (95% CI, 0.953-0.996) using the modified scoring system. Pairwise comparison of these AUCs revealed a significant difference (P = 0.0032). The sensitivity and specificity for diagnosing malignancy with an ADNEX MR score of 4 or more were 95.5% and 86.6%, respectively, using the classic scoring system, and 95.7% and 93.3%, respectively, using the modified scoring system.
CONCLUSION: DWI with ADC mapping could be integrated into the ADNEX MR scoring system to improve specificity, thereby potentially optimizing clinical management by avoiding unnecessary surgery. © 2020 International Society of Ultrasound in Obstetrics and Gynecology.
引用
- Hottat NA, Van Pachterbeke C, Vanden Houte K, et al. Magnetic resonance scoring system for assessment of adnexal masses: added value of diffusion-weighted imaging including apparent diffusion coefficient map. Ultrasound Obstet Gynecol. 2021. PMID: 32438461. doi:10.1002/uog.22090
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。