文献速递妇产影像技术与安全US

基于母亲体重指数延迟胎儿解剖超声评估并未降低可视化不足的发生率

Delay of Fetal Anatomy Ultrasound Assessment Based on Maternal Body Mass Index Does Not Reduce the Rate of Inadequate Visualization.
PubMed 文献 · J Ultrasound Med · 2020-05-08

回顾性研究比较基于孕早期体重指数延迟初始胎儿解剖超声评估(B期)与标准孕18-19周评估(A期)的可视化不足率。B期可视化不足率略高于A期(16.9% vs 15.0%,P=0.03),调整后OR为1.2(95%CI 1.02-1.38)。在肥胖孕妇中,基于体重指数延迟评估至孕19周以后并未降低可视化不足率。

要点

  • 基于体重指数延迟至孕19周后评估并未降低可视化不足率,B期16.9% vs A期15.0%(P=0.03)。
  • 体重指数≥40 kg/m²时可视化不足率超过35%,无论是否延迟。
  • B期仅74%按方案执行,体重指数≥40 kg/m²组执行率降至52%。

临床应用与阅片要点

  • 调整母亲年龄和胎位后,B期可视化不足的比值比略高于A期(调整OR 1.2,95%CI 1.02-1.38)。
  • B期重复评估率与A期相似(14.0% vs 13.1%,P=0.25)。
  • 体重指数≥40 kg/m²时可视化不足率超过35%,无论是否延迟。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To determine whether delay of initial anatomy ultrasound based on the maternal body mass index (BMI) reduces the rate of inadequate visualization compared to standard timing at 180/7 to 196/7 weeks.

METHODS: A retrospective study of singleton anatomy assessments was conducted at a tertiary care center in the 2-year period before (A, 2012-2014) and after (B, 2014-2016) protocol initiation. Assessments in period B were scheduled on the basis of the BMI in the first trimester: lower than 25 kg/m2 , 180/7 to 196/7 weeks; 25 to 29.9 kg/m2 , 190/7 to 206/7 weeks; 30 to 34.9 kg/m2 , 200/7 to 216/7 weeks; 35 to 39.9 kg/m2 , 210/7 to 226/7 weeks; and 40 kg/m2 or higher, 220/7 to 236/7 weeks. In period A, assessments were scheduled between 180/7 and 196/7 weeks. The rate of inadequate visualization and repeated assessments in periods A and B were compared. Multivariable logistic regression, per-protocol, and BMI subgroup analyses were completed.

RESULTS: In total, 3491 pregnancies in period A and 3672 in period B were included. In period B, 74% were scheduled per protocol; however, this rate decreased for higher-BMI categories (52% for BMI ≥40 kg/m2 ). The inadequate visualization rate was slightly higher in period B versus A (16.9% versus 15.0%; P = .03) and exceeded 35% for a BMI of 40 kg/m2 or higher, with or without delay. After adjusting for maternal age and fetal presentation, period B had small increased odds of inadequate visualization versus period A (adjusted odds ratio, 1.2; 95% confidence interval, 1.02-1.38). Repeated assessment rates were similar in periods B and A (14.0% versus 13.1%; P = .25).

CONCLUSIONS: In pregnancies with obesity, a protocol delaying the initial assessment beyond 196/7 weeks based on the maternal BMI does not reduce the rate of inadequate visualization.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Khaikin Y, Bishop KA, Munawar S, et al. Delay of Fetal Anatomy Ultrasound Assessment Based on Maternal Body Mass Index Does Not Reduce the Rate of Inadequate Visualization. J Ultrasound Med. 2020. PMID: 32383804. doi:10.1002/jum.15319

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。