文献速递腹部泌尿生殖技术与安全CT

是时候关注(准直)框内了:一项减少肾-输尿管-膀胱CT过度扫描的质量改进项目

It is time to think inside the (collimation) box; a quality improvement project to reduce over-scanning in CT scanning of the kidneys, ureters and bladder.
PubMed 文献 · Br J Radiol · 2020-05-27

该质量改进项目回顾性分析一家区综合医院100例因肾绞痛行CT肾-输尿管-膀胱(CTKUB)检查的患者,按皇家放射科医学院(RCR)标准(最高肾上极以上多余扫描长度不应超过总扫描长度的10%)评估,81%的扫描超出标准。实施实时观察图像采集并在最高肾上极手动停止扫描后,复查50例,过度扫描降至14%。

要点

  • CTKUB扫描长度超过最高肾上极以上10%总扫描长度的比例在干预前为81%(81/100)。
  • 实时观察图像采集并手动在最高肾上极停止扫描后,过度扫描比例降至14%(7/50)。
  • 对CTKUB扫描技术做小改动即可显著提高对RCR指南的依从性。

核心结论

  • 该区综合医院对大部分患者存在过度扫描,手动停止CTKUB扫描显著减少了过度扫描。

研究设计与样本

  • 回顾性研究,纳入100例连续因肾绞痛至放射科就诊的患者,记录最高肾上极以上CTKUB层数相对于扫描长度的比例,并对照RCR标准(最高肾上极以上多余扫描长度不应超过总扫描长度的10%)进行评估。
  • 干预为放射技师实时观察图像采集并在最高肾上极手动停止扫描,实施后对50例患者进行复查。

诊断标准与关键数值

  • RCR标准:CTKUB扫描长度超过最高肾上极以上的部分不应超过总扫描长度的10%。
  • 干预前过度扫描比例为81%(81/100),干预后为14%(7/50)。

临床应用与阅片要点

  • RCR推荐CTKUB作为肾绞痛的一线检查,并指出最高肾上极以上多余扫描长度不应超过总扫描长度的10%。
  • 放射技师可实时观察图像采集并在最高肾上极手动停止扫描,以减少过度扫描。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The Royal College of Radiologists (RCR) recommend CT of the kidneys, ureters and bladder (CTKUB) as the first-line investigation for renal colic, stating that excess scan length above the upper pole of the highest kidney should not exceed 10% of the total scan length. The project aim was to determine what proportion of CTKUB scans performed at a district general hospital (DGH) were meeting this standard and explore improvement options as necessary.

METHODS: A retrospective study was performed on 100 consecutive patients who attended a Radiology Department with renal colic. The number of CTKUB slices above the upper pole of the highest kidney, relative to scan length, was recorded. The DGH radiographers believed over scanning could be reduced by viewing image acquisition in real-time and manually stopping the scan at the top of the highest kidney. This was implemented and a re-audit of 50 patients was performed.

RESULTS: Scan length exceeded the standard on 81% of scans (81/100). Over scanning was reduced to 14% (7/50) post-intervention.

CONCLUSION: This DGH was over scanning a large proportion of patients. Manually stopping the CTKUB significantly reduced over scanning.

ADVANCES IN KNOWLEDGE: A small change to CTKUB scanning technique can significantly improve adherence to RCR guidelines.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Netke T, Spurr M, Vosough A, et al. It is time to think inside the (collimation) box; a quality improvement project to reduce over-scanning in CT scanning of the kidneys, ureters and bladder. Br J Radiol. 2020. PMID: 32459517. doi:10.1259/bjr.20200068

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。