ADC比值在多参数前列腺MRI中鉴别真阳性与假阳性的准确性
回顾性评估73例患者98个前列腺病灶,两名放射科医生双盲测量病灶与对侧良性前列腺实质的ADC比值,以活检Gleason评分≥6为参考标准。ADC均值比和最小-最大值比的AUC分别为0.72/0.67(读者1)和0.74/0.71(读者2),ADC均值比最佳阈值≥0.5和≥0.6时敏感度76.3%和84.2%、特异度51.7%和50%。结论认为ADC比值是诊断前列腺癌有用且中等准确的补充工具。
要点
- ADC比值鉴别前列腺癌真阳性与假阳性仅中等准确,AUC 0.67–0.74。
- ADC均值比阈值≥0.6时读者1未漏诊临床显著前列腺癌,读者2仅漏诊1例。
- ADC比值特异度约50%,需结合其他mpMRI序列综合判断。
核心结论
- ADC比值是诊断前列腺癌有用且中等准确的补充工具。
研究设计与样本
- 回顾性研究,纳入2016至2018年本院73例患者共98个前列腺病灶,均行前列腺mpMRI和标准12针前列腺活检。
- 两名经验丰富的放射科医生双盲对MRI identified病灶及对侧表现良性前列腺实质在约10 mm²圆形感兴趣区内进行ADC值定量。
- 自动计算病灶均值与良性实质均值之比(ADC ratio mean)以及病灶最小值与良性实质最大值之比(ADC ratio min-max)。
- 以活检Gleason评分≥6及定位确定病灶恶性。
诊断标准与关键数值
- 读者1的ADC ratio mean和ADC ratio min-max的AUC分别为0.72和0.67,读者2分别为0.74和0.71。
- ADC ratio mean最佳截断值读者1为≥0.5、读者2为≥0.6,敏感度分别为76.3%和84.2%,特异度分别为51.7%和50%。
- 以0.6为阈值,读者1未漏诊临床显著前列腺癌,读者2仅漏诊1例。
临床应用与阅片要点
- ADC比值可作为mpMRI诊断前列腺癌的补充工具,但特异度约50%,需结合其他序列综合判读。
- 作者认为ADC比值是诊断前列腺癌有用且中等准确的补充工具。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Our goal was to evaluate the usefulness of apparent diffusion coefficient (ADC) ratios in discriminating true from false positives in multiparametric (mp) prostate MRI in clinical practice.
METHODS: We retrospectively evaluated 98 prostate lesions in a series of 73 patients who had undergone prostate mpMRI and standard 12-core prostatic biopsy in our institution from 2016 to 2018. Two experienced radiologists performed double blind ADC value quantifications of both MRI-identified lesions and apparently benign contralateral prostatic parenchyma in a circular region of interest (ROI) of ∼10 mm2. The ratios between the mean values of both measurements (i.e., ADC ratio mean) and between the minimum value of the lesion and the maximum value of the benign parenchyma (i.e., ADC ratio min-max) were automatically calculated. The malignancy of all lesions was determined through biopsy according to Gleason score (GS ≥ 6) and localization.
RESULTS: For Reader 1, the area under the ROC curve (AUC) of ADC ratio mean and ADC ratio min-max were 0.72 and 0.67, respectively, whereas for Reader 2 these values were 0.74 and 0.71, respectively. The best cut-off values for ADC ratio means were ≥ 0.5 (Reader 1) and ≥ 0.6 (Reader 2), with a sensitivity of 76.3 % and 84.2 % and a specificity of 51.7 % and 50 %, respectively. Moreover, based on a threshold of 0.6, no clinically significant prostate cancer (csPCa) was missed by Reader 1, while only one went unnoticed by Reader 2.
CONCLUSION: The ADC ratio is a useful and moderately accurate complementary tool to diagnose prostate cancer in the mp-MRI.
引用
- Falaschi Z, Valenti M, Lanzo G, et al. Accuracy of ADC ratio in discriminating true and false positives in multiparametric prostatic MRI. Eur J Radiol. 2020. PMID: 32387923. doi:10.1016/j.ejrad.2020.109024
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。