MRI上肿瘤包膜接触长度检测前列腺癌前列腺外延伸的诊断效能:系统综述与Meta分析
该系统综述与Meta分析纳入13篇文献共2136例患者,评估MRI上肿瘤包膜接触长度(LCC)诊断前列腺癌前列腺外延伸(EPE)的效能,汇总敏感度0.79(95%CI 0.73-0.83)、特异度0.67(95%CI 0.60-0.74),HSROC曲线下面积0.81(95%CI 0.77-0.84),结论为LCC越大EPE概率越高,但因研究间异质性,需进一步研究确定各临床场景的最佳截断值。
要点
- MRI上肿瘤包膜接触长度(LCC)越大,前列腺癌前列腺外延伸(EPE)的概率越高。
- 汇总敏感度0.79(95%CI 0.73-0.83)、特异度0.67(95%CI 0.60-0.74),HSROC曲线下面积0.81(95%CI 0.77-0.84)。
- 测量方法(曲线 vs 直线)、Gleason评分≥7的患病率、MRI阅片者经验和直肠内线圈是异质性的显著因素(p≤0.01)。
核心结论
- MRI上LCC越大与前列腺癌EPE概率越高相关。
- 因研究间存在异质性,需进一步研究以确定各临床场景的最佳截断值。
研究设计与样本
- 系统综述与Meta分析,检索PubMed和EMBASE数据库至2019年3月24日。
- 纳入13篇文献共2136例患者,评估MRI上LCC检测EPE的诊断准确性研究。
- 参考标准为根治性前列腺切除术标本组织病理学。
- 采用诊断准确性研究质量评价工具-2(QUADAS-2)评估研究质量,质量总体良好。
诊断标准与关键数值
- 汇总敏感度0.79(95%CI 0.73-0.83),汇总特异度0.67(95%CI 0.60-0.74)。
- HSROC曲线下面积0.81(95%CI 0.77-0.84)。
- Cochran Q检验(p<0.01)和Higgins I²(敏感度62%、特异度86%)提示存在显著异质性。
- 测量方法(曲线 vs 直线)、Gleason评分≥7的患病率、MRI阅片者经验和直肠内线圈是异质性的显著因素(p≤0.01);LCC阈值确定方法、截断值、磁场强度和发表年份不是显著因素(p=0.14-0.93)。
- 各评估的MRI序列间诊断准确性估计值相当。
局限性
- 研究间存在显著异质性,Cochran Q检验p<0.01,Higgins I²敏感度62%、特异度86%。
- 需进一步研究以确定每个临床场景的最佳截断值。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The purpose was to review the diagnostic performance of the length of tumor capsular contact (LCC) on magnetic resonance imaging (MRI) for detecting prostate cancer extraprostatic extension (EPE).
MATERIALS AND METHODS: PubMed and EMBASE databases were searched up to March 24, 2019. We included diagnostic accuracy studies that evaluated LCC on MRI for EPE detection using radical prostatectomy specimen histopathology as the reference standard. Quality of studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Sensitivity and specificity were pooled and graphically presented using hierarchical summary receiver operating characteristic (HSROC) plots. Meta-regression and subgroup analyses were conducted to explore heterogeneity.
RESULTS: Thirteen articles with 2136 patients were included. Study quality was generally good. Summary sensitivity and specificity were 0.79 (95% confidence interval [CI] 0.73-0.83) and 0.67 (95% CI 0.60-0.74), respectively. Area under the HSROC was 0.81 (95% CI 0.77-0.84). Substantial heterogeneity was present among the included studies according to Cochran's Q-test (p < 0.01) and Higgins I² (62% and 86% for sensitivity and specificity, respectively). In terms of heterogeneity, measurement method (curvilinear vs. linear), prevalence of Gleason score ≥ 7, MRI readers' experience, and endorectal coils were significant factors (p ≤ 0.01), whereas method to determine the LCC threshold, cutoff value, magnet strength, and publication year were not (p = 0.14-0.93). Diagnostic test accuracy estimates were comparable across all assessed MRI sequences.
CONCLUSION: Greater LCC on MRI is associated with a higher probability of prostate cancer EPE. Due to heterogeneity among the studies, further investigation is needed to establish the optimal cutoff value for each clinical setting.
引用
- Kim TH, Woo S, Han S, et al. The Diagnostic Performance of the Length of Tumor Capsular Contact on MRI for Detecting Prostate Cancer Extraprostatic Extension: A Systematic Review and Meta-Analysis. Korean J Radiol. 2020. PMID: 32410407. doi:10.3348/kjr.2019.0842
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。