比较糖尿病合并与不合并糖尿病肾病患者超音速剪切波成像所测肾实质硬度
研究纳入124例受试者,分为健康组31例、2型糖尿病无肾病组38例和糖尿病肾病组55例,采用超音速剪切波成像测量肾实质杨氏模量。平均杨氏模量鉴别糖尿病肾病的ROC曲线下面积最大为0.860, cutoff值31.73 kPa,敏感度85.5%、特异度71.0%;平均杨氏模量与胱抑素C、尿素、肌酐、尿酸、白蛋白/肌酐比值及糖尿病视网膜病变呈正相关,与估算肾小球滤过率呈负相关。
要点
- 平均杨氏模量鉴别糖尿病肾病的AUC为0.860,优于常规超声参数及最小、最大杨氏模量。
- 平均杨氏模量cutoff值31.73 kPa,诊断糖尿病肾病敏感度85.5%、特异度71.0%。
- 2型糖尿病无肾病组平均杨氏模量31.44±3.83 kPa,高于健康组26.45±4.32 kPa,低于糖尿病肾病组37.60±6.56 kPa。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
This study aims to evaluate the difference in renal parenchyma stiffness assessed by measuring Young's modulus (YM) using a supersonic shear wave imaging (SSI) technique among healthy patients and patients with type 2 diabetes mellitus (DM) with and without diabetic kidney disease (DKD). We analyzed the correlations of YM with clinical information and conventional ultrasound parameters. All patients (N = 124) were divided into three groups: (i) healthy patients (patients without kidney disease or type 2 DM, N = 31); (ii) patients with type 2 DM without kidney disease (N = 38); and (iii) patients with DKD (N = 55). Conventional and SSI ultrasound examinations were performed in all individuals for both kidneys. Then, we recorded renal length, width, parenchyma thickness, interlobar arterial resistive index (RI) and values of mean, mininum and maximum YM. The mean values of these parameters for the left and right kidneys were calculated for statistical analysis. Statistical significance was considered at p < 0.05. Among all ultrasound parameters, the mean YM demonstrated the largest area under the receiver operating characteristic (ROC) curve (0.860). The areas under the ROC curve (AUCs) for renal length, width, parenchyma thickness, interlobar arterial RI, minimum YM and maximum YM were 0.493, 0.616, 0.507, 0.733, 0.848 and 0.794, respectively. The corresponding cutoff value of mean YM was 31.73 kPa, with a sensitivity of 85.5% and a specificity of 71.0%. The mean YM in patients with type 2 DM without kidney disease (31.44 ± 3.83 kPa) was significantly higher than that in the healthy group (26.45 ± 4.32 kPa) and lower than that in the DKD group (37.60 ± 6.56 kPa). Patients with type 2 DM without kidney disease were considered as stage 0 of DKD. Thus, the mean YM in the control group was significantly lower than that in the stage 0, 2, 3, 4 and 5 subgroups. The mean YM in the stage 0-2 subgroups was lower than that in the stage 5 group, and the mean YM in the stage 0 group was lower than that in the stage 4 group. In the DKD group, the mean YM had a positive correlation with cystine-c (r = 0.634), urea (r = 0.596), creatine (r = 0.690), uric acid (r = 0.263), albumin/creatinine ratio (r = 0.428) and the presence or absence of diabetic retinopathy (r = 0.354). The mean YM also had a negative correlation with the estimated glomerular filtration rate (r = -0.657). SSI is a non-invasive method with which to diagnose DKD and has a performance superior to that of conventional ultrasound. In addition, SSI may provide a secondary index for the staging of DKD and the monitoring of renal damage in type 2 DM patients.
引用
- Shi LQ, Sun JW, Miao HH, et al. Comparison of Supersonic Shear Wave Imaging-Derived Renal Parenchyma Stiffness Between Diabetes Mellitus Patients With and Without Diabetic Kidney Disease. Ultrasound Med Biol. 2020. PMID: 32404297. doi:10.1016/j.ultrasmedbio.2020.03.026
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。