腹部双源多期动态CT图像质量:低管电压(70 kVp)联合对比剂剂量减半的效果评估
本研究对55例成人患者自身对照,比较70 kVp联合半剂量碘负荷低浓度对比剂与120 kVp全剂量碘负荷的腹部多期动态CT图像质量。结果显示70 kVp方案在肝脏、主动脉及门静脉的CT值和SNR更高,图像质量主观评分更优,作者认为该方案可能改善体重71 kg以下患者的多期腹部CT增强效果和图像质量。
要点
- 70 kVp联合半剂量碘负荷方案在动脉期、门脉期及平衡期肝脏实质CT值和SNR均显著高于120 kVp全剂量方案。
- 70 kVp方案在三期图像整体质量主观评分上均显著优于120 kVp方案。
- 平衡期肝实质和肝静脉对比增强评分在70 kVp方案中显著更高。
核心结论
- 在高管输出双源CT上,70 kVp联合半剂量碘负荷低浓度对比剂及迭代重建算法可能改善体重71 kg以下患者腹部多期动态CT的对比增强和图像质量。
研究设计与样本
- 自身对照研究,纳入55例同时接受70 kVp半剂量碘负荷和120 kVp全剂量碘负荷腹部CT的成人患者,在高管输出双源CT上采集动脉期、门脉期和平衡期图像。
关键影像表现/征象
- 70 kVp方案下肝脏实质的平均CT值和SNR在全部3期中均显著高于120 kVp方案(p=0.018至<0.001)。
- 70 kVp方案下全部3期的整体图像质量主观评分均显著优于120 kVp方案(p<0.001)。
- 70 kVp方案下平衡期肝实质和肝静脉的对比增强评分均显著高于120 kVp方案(p<0.001)。
临床应用与阅片要点
- 作者认为,对于体重71 kg以下患者,采用70 kVp联合半剂量碘负荷低浓度对比剂及迭代重建算法的双源CT多期腹部动态扫描可能改善图像质量和对比增强。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To compare the image quality of multiphasic (arterial, portal, and equilibrium phases) dynamic computed tomography (CT) of the abdomen obtained by a low tube voltage (70kVp) in combination with a half-dose iodine load using low-concentration contrast agent in high tube output dual-source CT with a standard tube voltage (120kVp) and full-dose iodine load using the same group of adult patients.
METHODS: Fifty-five patients who underwent both low-tube-voltage (70kVp) abdominal CT with a half-dose iodine load and standard-tube-voltage (120kVp) CT with a full-dose iodine load were analyzed. The mean CT values and signal-to-noise ratio (SNR) of the liver, aorta and portal veins were quantitatively assessed. In addition, the contrast enhancement of the abdominal organs and overall image quality were qualitatively evaluated.
RESULTS: The mean CT values and SNR of the liver parenchyma were significantly higher in 70-kVp protocol than in 120-kVp protocol in all 3 phases (p = 0.018 ~ < 0.001). Regarding the qualitative analysis, the overall image quality in the 70-kVp protocol was significantly better than in the 120-kVp protocol in all 3 phases (p < 0.001). In addition, the contrast enhancement scores of the liver parenchyma and hepatic vein in the equilibrium phase were also significantly higher in the 70-kVp protocol than in the 120-kVp protocol (p < 0.001).
CONCLUSION: A low tube voltage (70kVp) in combination with a half-dose iodine load using a low-concentration contrast agent and an iterative reconstruction algorithm in high tube output dual-source CT may improve the contrast enhancement and image quality in multiphasic dynamic CT of the abdomen in patients under 71 kg of body weight.
引用
- Miyoshi K, Onoda H, Tanabe M, et al. Image quality in dual-source multiphasic dynamic computed tomography of the abdomen: evaluating the effects of a low tube voltage (70 kVp) in combination with contrast dose reduction. Abdom Radiol (NY). 2020. PMID: 32382819. doi:10.1007/s00261-020-02565-9
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。