双能CT半自动分割与影像组学鉴别良恶性肝脏病变的初步研究
本研究纳入103例成年患者(良性60例、恶性43例)的对比增强双源双能CT图像,用原型软件半自动分割病灶并提取碘定量与影像组学特征。良恶性病变的归一化碘浓度和平均碘浓度有显著差异(AUC 0.695–0.856),病灶边缘的碘定量与影像组学特征鉴别准确度更高(AUC≤0.877),DECT碘定量(AUC 0.91)与影像组学(AUC 0.90)的鉴别准确度无差异。
要点
- 病灶边缘的碘定量与影像组学特征鉴别良恶性肝脏病变的AUC≤0.877,高于病灶整体体积的AUC≤0.856。
- DECT碘定量(AUC 0.91)与影像组学(AUC 0.90)鉴别肝脏病变的准确度无差异。
- 良恶性病变的归一化碘浓度和平均碘浓度差异显著(p<0.0001–0.0084;AUC 0.695–0.856)。
核心结论
- DECT影像组学鉴别实性良恶性肝脏病变的准确度高于碘定量。
研究设计与样本
- 经机构审查委员会批准的初步研究,纳入103例成年患者(平均年龄65±15岁;男53例、女50例),良性病变60例、恶性病变43例。
- 采用对比增强双源DECT,多数恶性病变经组织学证实,良性病变经随访CT稳定或MRI具良性特征确认。
- 低千伏与高千伏数据集去标识后离线导出,用DECT肿瘤分析原型对每个肝脏病灶的体积和边缘进行半自动分割。
- 对每个分割提取对比增强、碘浓度及不同DECT图像系列的影像组学特征,并进行统计分析。
关键影像表现/征象
- 评估对比增强双能CT上良恶性肝脏病变的半自动分割与影像组学特征。
诊断标准与关键数值
- 归一化碘浓度和平均碘浓度在良恶性病变间差异显著(p<0.0001–0.0084;AUC 0.695–0.856)。
- 病灶边缘的碘定量与影像组学特征鉴别肝脏病变的AUC≤0.877,高于病灶体积的AUC≤0.856。
- DECT碘定量(AUC 0.91)与影像组学(AUC 0.90)鉴别肝脏病变的准确度无差异。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. This study assessed a machine learning-based dual-energy CT (DECT) tumor analysis prototype for semiautomatic segmentation and radiomic analysis of benign and malignant liver lesions seen on contrast-enhanced DECT. MATERIALS AND METHODS. This institutional review board-approved study included 103 adult patients (mean age, 65 ± 15 [SD] years; 53 men, 50 women) with benign (60/103) or malignant (43/103) hepatic lesions on contrast-enhanced dual-source DECT. Most malignant lesions were histologically proven; benign lesions were either stable on follow-up CT or had characteristic benign features on MRI. Low- and high-kilovoltage datasets were deidentified, exported offline, and processed with the DECT tumor analysis for semiautomatic segmentation of the volume and rim of each liver lesion. For each segmentation, contrast enhancement and iodine concentrations as well as radiomic features were derived for different DECT image series. Statistical analyses were performed to determine if DECT tumor analysis and radiomics can differentiate benign from malignant liver lesions. RESULTS. Normalized iodine concentration and mean iodine concentration in the benign and malignant lesions were significantly different (p < 0.0001-0.0084; AUC, 0.695-0.856). Iodine quantification and radiomic features from lesion rims (AUC, ≤ 0.877) had higher accuracy for differentiating liver lesions compared with the values from lesion volumes (AUC, ≤ 0.856). There was no difference in the accuracies of DECT iodine quantification (AUC, 0.91) and radiomics (AUC, 0.90) for characterizing liver lesions. CONCLUSION. DECT radiomics were more accurate than iodine quantification for differentiating solid benign and malignant hepatic lesions.