虚拟单能图像与迭代重建:光谱探测器CT时代的腹部血管成像
回顾性分析50例腹部动脉期扫描,比较双层光谱探测器CT的虚拟单能图像(VMI40keV、VMI70keV、VMI100keV)与多色图像(混合迭代重建PCIHIR、基于模型重建PCIMBR)对主动脉及腹部分支的显示质量;VMI40keV与VMI70keV的信噪比/对比噪声比优于PCIHIR和PCIMBR,但PCIMBR显示动脉粥样硬化斑块最佳,作者推荐在常规CT用PCIMBR、在光谱探测器CT用VMI40keV并辅以VMI100keV进行腹部动脉诊断评估。
要点
- VMI40keV的SNR和CNR最高,主观对比度和噪声评分也优于PCIMBR、VMI70keV和PCIHIR。
- PCIMBR显示软斑块和微钙化最佳,VMI100keV显示微钙化第二好且显示粗钙化与PCIMBR相当。
- VMI40keV显示软斑块第二好,VMI100keV的CNR和SNR最低。
关键影像表现/征象
- VMI40keV的S-/CNR最高(p≤0.001)。
- VMI70keV与PCIMBR的SNR相当(p≥0.999),且均高于PCIHIR。
- VMI70keV的CNR高于PCIHIR(p<0.001)和PCIMBR(p<0.045)。
- VMI100keV的CNR最低(p≤0.001),SNR也最低(p≥0.104)。
- 主观分析中,VMI40keV的对比度和噪声评分优于PCIMBR,PCIMBR优于VMI70keV,VMI70keV优于PCIHIR(均p<0.001)。
诊断标准与关键数值
- PCIMBR显示软斑块和微钙化最佳(p<0.001)。
- VMI100keV显示微钙化第二好(p<0.001),显示粗钙化与PCIMBR相当(p>0.999)。
- VMI40keV显示软斑块第二好(p<0.020)。
临床应用与阅片要点
- 作者推荐在常规CT上使用PCIMBR,在光谱探测器CT上使用VMI40keV并辅以VMI100keV进行腹部动脉的诊断评估。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To compare the quality of virtual mono-energetic (VMI) and polychromatic images reconstructed with hybrid iterative (PCIHIR) or model-based reconstruction (PCIMBR) derived from dual-layer spectral detector computed tomography (SDCT) in arterial phase images to visualise the aorta and abdominal main branches.
MATERIAL AND METHODS: A retrospective review of 50 patients with abdominal arterial phase scans was undertaken. Attenuation, intraluminal noise, and signal-/contrast-to-noise ratio (S-/CNR) were assessed in the PCIHIR, PCIMBR and VMI40keV, VMI70keV, and VMI100keV images. Contrast, noise, and visualization of soft-plaque, and macro-/micro-calcifications were scored in a blinded reading by two radiologists.
RESULTS: VMI40keV yielded highest S-/CNR (p≤0.001). VMI70keV and PCIMBR showed comparable SNR (p≥0.999) and yielded higher SNR than PCIHIR. VMI70keV yielded higher CNR than PCIHIR (p<0.001) and PCIMBR (p<0.045). VMI100keV yielded lowest CNR (p≤0.001) and SNR (p≥0.104). In the subjective analysis, VMI40keV outperformed PCIMBR for contrast and noise, PCIMBR scored better than VMI70keV, and the latter scored better than PCIHIR for these categories (all p<0.001). PCIMBR was superior for depiction of soft-plaque and micro-calcifications (p<0.001). VMI100keV visualized micro-calcifications second best (p<0.001) and matched PCIMBR for the depiction of macro-calcifications (p>0.999), while VMI40keV scored second best for depiction of soft-plaque (p<0.020).
CONCLUSIONS: VMI40keV and VMI70keV yield better S-/CNR than PCIHIR and PCIMBR; however, PCIMBR visualized arteriosclerotic plaques best, followed by VMI40keV for depiction of soft-plaque and VMI100keV for macro- and micro-calcification. Based on the present findings, PCIMBR on conventional CT and VMI40keV supplemented by VMI100keV on SDCT are recommended for the diagnostic assessment of abdominal arteries.
引用
- Al-Baldawi Y, Große Hokamp N, Haneder S, et al. Virtual mono-energetic images and iterative image reconstruction: abdominal vessel imaging in the era of spectral detector CT. Clin Radiol. 2020. PMID: 32362502. doi:10.1016/j.crad.2020.03.036
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。