脾和肝弹性成像及彩色多普勒超声在评估经颈静脉肝内门体分流术功能中的作用。
评估经颈静脉肝内门体分流术(TIPS)功能的参考标准是静脉造影并测量门体压力梯度(PPG)。该操作有创且昂贵;因此,我们评估了彩色多普勒超声(CDUS)及脾和肝硬度(LS)测量在识别TIPS功能障碍方面的可行性、可重复性和诊断准确性。…
要点
- pSWE测脾硬度可重复性好(ICC 0.90,95%CI 0.81‒0.94)。
- 脾硬度诊断TIPS功能障碍AUROC 0.86(95%CI 0.70‒0.96),阈值25 kPa。
- 肝内门静脉分支血流方向与脾硬度值可独立关联TIPS功能障碍。
英文原文(摘要)· 点击展开
The reference standard for assessing transjugular intrahepatic portosystemic shunt (TIPS) function is venography with portosystemic pressure gradient (PPG) measurement. This procedure is invasive and expensive; thus, we assessed the feasibility, reproducibility and diagnostic accuracy of color-Doppler ultrasound (CDUS) and spleen and liver stiffness (LS) measurements for identifying TIPS dysfunction. Twenty-four patients (15 undergoing TIPS placement and nine undergoing TIPS revision) consecutively underwent CDUS examination and LS and spleen stiffness (SS) determination by transient elastography (TE) and point shear-wave elastography (pSWE). All parameters were taken before TIPS placement/revision (1-15 d before) and 24 h after, just before revision by venography. pSWE inter-observer agreement was assessed by intra-class correlation coefficient (ICC). CDUS and elastographic data were correlated (Pearson coefficient) with pressure gradients (hepatic venous pressure gradient [HVPG], PPG). Main determinants of TIPS dysfunction were investigated by linear regression. Forty-nine paired examinations were performed in total: 49 (100%) SS reliable measurements by pSWE and 38 (88%) by TE. The ICC for pSWE values was 0.90 (95% confidence interval [CI] 0.81‒0.94). SS values significantly correlated with HVPG and PPG (R = 0.51, p = 0.01). The area under the Receiver-Operating Characteristic (AUROC) curve of SS for diagnosing TIPS dysfunction was 0.86 (95% CI 0.70‒0.96) using a 25 kPa cutoff. At multivariate analysis, the flow direction of the intrahepatic portal vein branches and SS values were independently associated to TIPS dysfunction. The intrahepatic portal vein branches flow direction and SS value are two simple, highly sensitive parameters accurately excluding TIPS dysfunction. SS measurement by pSWE is feasible, reproducible and both positively and significantly correlates with HVPG and PPG values.
引用
- Giunta M, La Mura V, Conti CB, et al. The Role of Spleen and Liver Elastography and Color-Doppler Ultrasound in the Assessment of Transjugular Intrahepatic Portosystemic Shunt Function. Ultrasound Med Biol. 2020. PMID: 32402671. doi:10.1016/j.ultrasmedbio.2020.04.007
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。