双能CT定量胰腺脂肪:与六点Dixon磁共振成像的比较
本研究纳入28例无对比剂双能CT(100和150 kVp)与Dixon MRI检查患者,在双能CT多材料分解算法生成的脂肪体积分数图上测量胰腺头、体/尾CT-FVF,并与Dixon MRI的MR-FVF比较。胰腺头CT-FVF与MR-FVF显著相关(ρ=0.631,P<0.001),体/尾亦显著相关(ρ=0.526,P=0.004)。作者认为双能CT可能有助于定量胰腺脂肪变性程度。
要点
- 双能CT脂肪体积分数与Dixon MRI在胰腺头(ρ=0.631)和体/尾(ρ=0.526)均显著相关。
- 胰腺头CT-FVF中位14.2%,体/尾中位9.4%;MR-FVF头中位12.2%,体/尾中位8.1%。
- 双能CT或可用于胰腺脂肪变性的定量评估。
诊断标准与关键数值
- 胰腺头CT-FVF中位14.2%(范围0.1-81.2%),体/尾中位9.4%(范围0-40.8%)。
- 胰腺头MR-FVF中位12.2%(范围1.2-80.9%),体/尾中位8.1%(范围0.3-43.7%)。
- 胰腺头CT-FVF与MR-FVF显著相关(ρ=0.631,P<0.001)。
- 胰腺体/尾CT-FVF与MR-FVF显著相关(ρ=0.526,P=0.004)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Although it is important to quantify the degree of fatty degeneration of the pancreas, it is difficult to make such a quantification using conventional computed tomography (CT). The present study evaluated the feasibility of pancreatic fat quantification by dual-energy CT (DECT) compared with T2*-corrected six-point Dixon magnetic resonance imaging (MRI).
MATERIALS AND METHODS: Twenty-eight patients who underwent both DECT (100 and 150 kVp) and Dixon MRI without the use of contrast agents were analyzed. The region of interest (ROI) was placed at the head and body/tail of the pancreas on fat volume fraction (FVF) maps generated using the multi-material decomposition (MMD) algorithm on DECT. The FVF (%) of pancreatic parenchyma measured by DECT (CT-FVF) was compared with that measured on FVF maps calculated using Dixon MRI (MR-FVF) using the Spearman rank correlation coefficient.
RESULTS: The median CT-FVF (%) values of the head and body/tail of the pancreas on DECT were 14.2% (range 0.1-81.2%) and 9.4% (range 0-40.8%), respectively. The median MR-FVF (%) values of the head and body/tail of the pancreas on Dixon MRI were 12.2% (range 1.2-80.9%) and 8.1% (range 0.3-43.7%), respectively. CT-FVF (%) measured by DECT showed a significant correlation with the MR-FVF (%) measured by Dixon MRI in the head of the pancreas (ρ = 0.631, P < 0.001) as well as the body/tail of the pancreas (ρ = 0.526, P = 0.004).
CONCLUSION: DECT may be useful for quantifying the degree of fatty degeneration of the pancreas.
引用
- Kameda F, Tanabe M, Onoda H, et al. Quantification of pancreas fat on dual-energy computed tomography: comparison with six-point Dixon magnetic resonance imaging. Abdom Radiol (NY). 2020. PMID: 32430511. doi:10.1007/s00261-020-02583-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。