文献速递心血管MR

固定短反转时间的新型磁共振晚期钆增强在缺血性心肌瘢痕中的应用

Novel Magnetic Resonance Late Gadolinium Enhancement With Fixed Short Inversion Time in Ischemic Myocardial Scars.
PubMed 文献 · Invest Radiol · 2020-01-01

本研究在64例陈旧性心肌梗死患者中比较固定短反转时间(TI=100毫秒)的3D单次屏气短LGE序列与个体化调整TI的标准3D LGE序列,短LGE显示197个梗死节段(18.1%)而标准LGE显示191个(17.6%),短LGE整体瘢痕可见度更优(4.2 vs 3.0,P=0.01),尤其对心内膜下梗死。

要点

  • 短LGE采用固定TI=100毫秒,无需心肌置零,单次屏气完成3D采集。
  • 短LGE对心内膜下梗死的瘢痕可见度优于标准LGE(4.2 vs 3.0,P=0.01)。
  • 短LGE与标准LGE透壁性评分无显著差异(P=0.8),采集时间相近。

关键影像表现/征象

  • 短LGE表现为暗瘢痕和亮血池,整体瘢痕可见度评分优于标准LGE(4.2 vs 3.0,5=可见度极佳;P=0.01)。
  • 短LGE较标准LGE的信号强度比值:瘢痕/血池为1.42,瘢痕/远端心肌为0.8,远端心肌/血池为0.22。
  • 短LGE检出197个梗死节段(18.1%),标准LGE检出191个(17.6%)。
  • 短LGE测得的纤维组织及总纤维百分比高于标准LGE(P=0.04),心肌质量无显著差异(P=0.5)。

诊断标准与关键数值

  • 短LGE瘢痕可见度评分4.2 vs 标准LGE 3.0(5分Likert量表,5=可见度极佳,1=可见度差;P=0.01)。
  • 整体透壁性评分短LGE与标准LGE无显著差异(P=0.8;4=透壁,0=无瘢痕)。
  • 采集时间短LGE 26±4秒 vs 标准LGE 25±9秒(P=0.7)。

临床应用与阅片要点

  • 短LGE固定TI=100毫秒无需心肌置零,单次屏气即可完成3D采集,对心内膜下梗死显示更佳。
  • 短LGE图像呈暗瘢痕、亮血池对比,阅片时需注意与标准LGE图像表现不同。
  • 短LGE测得的纤维组织及总纤维百分比高于标准LGE(P=0.04),报告纤维化程度时需结合序列类型。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIMS: Late gadolinium enhancement (LGE) visualizes scar tissue after myocardial infarction. However, in clinically used LGE sequences, subendocardial infarcts can be missed due to low contrast between blood pool and subendocardium. The purpose of his study was to compare scar visibility in a novel 3-dimensional (3D) single breath-hold inversion recovery sequence with fixed, short inversion time (TI = 100 milliseconds) (short LGE) and standard 3D LGE imaging with individually adjusted TI (LGE).

METHODS: Short LGE and LGE (both sequences with the same settings: spatial resolution, 1.2 × 1.2 mm; slice thickness, 8 mm; field of view, 350 × 350 mm; single breath-hold) were acquired in 64 patients with previous MI (13 female; mean age, 57 ± 19 years) at 1.5 T. Inversion time was set to 100 milliseconds in short LGE and adjusted individually in LGE according to the Look-Locker sequence. Two independent readers evaluated 1088 segments (17-segment model), identified infarcted segments, and categorized scar visibility (5 = excellent, 1 = poor scar visibility) and scar transmurality (4 = transmural, 0 = no scar) using a 5-point Likert scale. Signal intensity ratios between short LGE and LGE for scar and blood pool, for scar and remote myocardium, and for remote myocardium and blood pool were calculated.

RESULTS: Short LGE showed 197 infarcted segments out of 1088 (18.1%); LGE revealed 191 segments (17.6%). Short LGE with dark scar and bright blood pool demonstrated better overall scar visibility, especially in subendocardially infarcted segments compared with LGE (4.2 vs 3.0, 5 = excellent visibility; P = 0.01). Signal intensity ratios for short LGE relative to LGE were 1.42 for scar/blood pool, 0.8 for scar/remote myocardium, and 0.22 for remote myocardium/blood.Overall transmurality was not rated higher in short LGE compared with LGE (P = 0.8). More fibrous tissue and total fibrous percentage (P = 0.04) were measured in short LGE compared with LGE, whereas myocardial mass was not significantly different (P = 0.5). Acquisition time was similar between short LGE and LGE (26 ± 4 seconds vs 25 ± 9 seconds, P = 0.7).

CONCLUSIONS: Short LGE is a fast, single breath-hold 3D LGE sequence with no need for myocardial nulling due to fixed inversion time with improved scar visibility, especially in subendocardial infarcts.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Polacin M, Gastl M, Kapos I, et al. Novel Magnetic Resonance Late Gadolinium Enhancement With Fixed Short Inversion Time in Ischemic Myocardial Scars. Invest Radiol. 2020. PMID: 32459683. doi:10.1097/RLI.0000000000000655

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。