氧敏感T2*磁共振成像关联出院后慢性心力衰竭患者心脏功能与缺血性病因
前瞻性纳入60名参与者(射血分数改善组20例、射血分数降低组20例、对照组20例),用T2*成像评估心肌氧合状态并与左心室射血分数(LVEF)比较。T2*值与LVEF正相关,射血分数降低组T2*值显著低于射血分数改善组和对照组(20.06 vs 24.23;20.06 vs 26.32,均p<0.05)。缺血性心力衰竭射血分数降低患者似乎更易出现心肌氧合降低,T2*测量可能临床可行。
要点
- 射血分数降低心衰组T2*值显著低于射血分数改善组和对照组。
- T2*值与LVEF呈正相关,缺血亚组T2*值低于非缺血亚组。
- T2*值与缺血区域心肌瘢痕数量无显著相关性。
关键影像表现/征象
- 射血分数降低组T2*值显著低于射血分数改善组(20.06 vs 24.23,p<0.05)。
- 射血分数降低组T2*值显著低于对照组(20.06 vs 26.32,p<0.05)。
- 缺血亚组T2*值低于非缺血亚组。
诊断标准与关键数值
- T2*值与LVEF呈正相关。
- 射血分数降低组 vs 射血分数改善组T2*值为20.06 vs 24.23(p<0.05)。
- 射血分数降低组 vs 对照组T2*值为20.06 vs 26.32(p<0.05)。
- T2*值与缺血区域心肌瘢痕数量无显著相关性。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Myocardial oxygenation imaging is a field-of-interest but its clinical utility largely unexplored. We aimed to investigate the myocardial oxygenation status via T2* imaging and compared with the left ventricular ejection fraction (LVEF) in chronic heart failure (HF) patients after hospitalization. Also, we sought to compare the differences in myocardial oxygenation status among patients with ischemic HF, non-ischemic HF and controls.
METHODS: We prospectively enrolled 60 participants, comprising 20 HF patients with LVEF ≥ 50 % as the improved ejection fraction (HFIEF) group, 20 H F patients with ejection fraction <50 % as the reduced ejection fraction (HFREF) group, and 20 controls. Patients were also dichotomized into ischemic and non-ischemic subgroups. T2* values were compared across the study groups, and correlated with LVEF, myocardial scar distribution and quantity.
RESULTS: T2* values positively correlated with LVEF and were significantly lower in the HFREF group as compared with both HFIEF and controls (20.06 vs. 24.23; 20.06 vs. 26.32, respectively, both p < 0.05). Lower T2* values were observed in the HFREF group than the HFIEF group and the ischemic subgroup than the non-ischemic subgroup. No significant correlation existed between T2* value and the myocardial scar amounts in ischemic territory.
CONCLUSIONS: Oxygen-sensitive T2* measurements showed correlation with LVEF and ischemic etiology in chronic heart failure patients, while the ischemic HFREF patients appeared to be more vulnerable to myocardial oxygen reduction than other groups. T2* measurements may be clinically feasible in monitoring heart failure via myocardial oxygenation and lay the foundation for future studies in prediction heart failure recovery.
引用
- Juan YH, Huang PC, Lin G, et al. Oxygen-sensitive T2* magnetic resonance imaging to correlate heart function and ischemic etiology of post-hospitalized chronic heart failure patients. Eur J Radiol. 2020. PMID: 32403031. doi:10.1016/j.ejrad.2020.109036
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。