对比剂与空间分辨率对特征追踪MRI心肌应变结果的影响
该前瞻性研究纳入75例患者,分析空间分辨率和钆对比剂对心脏磁共振特征追踪心肌应变的影响。低空间分辨率使A组存活心肌纵向应变升高、B组梗死心肌纵向、周向和径向应变均升高;钆对比剂使A组周向和径向应变降低,B组梗死组织应变无变化。作者认为标准化图像采集对CMR特征追踪似乎很重要。
要点
- 低空间分辨率(2.0×2.0×8 mm³)较标准分辨率(1.4×1.4×8 mm³)使A组存活心肌纵向应变升高(-21.7% vs -19.8%,p<0.001)。
- 低空间分辨率使B组梗死心肌纵向、周向和径向应变均升高(p=0.001、0.002、0.013)。
- 钆对比剂使A组周向和径向应变降低(p=0.001、0.016),B组梗死组织应变无变化。
诊断标准与关键数值
- A组存活心肌纵向应变:低空间分辨率 -21.7% vs 标准分辨率 -19.8%,p<0.001。
- B组梗死心肌纵向应变:低空间分辨率 -17.0% vs 标准分辨率 -14.3%,p=0.001。
- B组梗死心肌周向应变:低空间分辨率 -18.6% vs 标准分辨率 -14.6%,p=0.002。
- B组梗死心肌径向应变:低空间分辨率 36.8% vs 标准分辨率 31.0%,p=0.013。
- A组周向应变:注射钆对比剂后 -21.4% vs 未注射 -22.3%,p=0.001;径向应变:注射后 44.4% vs 未注射 46.9%,p=0.016。
临床应用与阅片要点
- 作者认为标准化图像采集对CMR特征追踪似乎很重要,应保持成像参数恒定且不使用对比剂。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Feature tracking for assessing myocardial strain from cardiac magnetic resonance (CMR) cine images detects myocardial deformation abnormalities with prognostic implication, e.g., in myocardial infarction and cardiomyopathy. Standards for image acquisition and processing are not yet available. Study aim was analyzing the influence of spatial resolution and contrast agent on myocardial strain results.
METHODS: Seventy-five patients underwent CMR for analyzing peak systolic circumferential, longitudinal, and radial strain. Group A included n = 50 with normal left ventricular ejection fraction, no wall motion abnormality, and no fibrosis on late enhancement imaging. Group B included n = 25 with chronic myocardial infarct. For feature tracking, steady-state free precession cine images were acquired repeatedly. (1) Native standard cine (spatial resolution 1.4 × 1.4 × 8 mm3). (2) Native cine with lower spatial resolution (2.0 × 2.0 × 8 mm3). (3) Cine equal to variant 1 acquired after administration of gadoteracid.
RESULTS: Lower spatial resolution was associated with elevated longitudinal strain (- 21.7% vs. - 19.8%; p < 0.001) in viable myocardium in group A, and with elevated longitudinal (- 17.0% vs. - 14.3%; p = 0.001), circumferential (- 18.6% vs. - 14.6%; p = 0.002), and radial strain (36.8% vs. 31.0%; p = 0.013) in infarcted myocardium in group B. Gadolinium administration was associated with reduced circumferential (- 21.4% vs. - 22.3%; p = 0.001) and radial strain (44.4% vs. 46.9%; p = 0.016) in group A, whereas strain results of the infarcted tissue in group B did not change after contrast agent administration.
CONCLUSIONS: Variations in spatial resolution and the administration of contrast agent may influence myocardial strain results in viable and partly in infarcted myocardium. Standardized image acquisition seems important for CMR feature tracking.
KEY POINTS: • Feature tracking is used for calculating myocardial strain from cardiac magnetic resonance (CMR) cine images. • This prospective study demonstrated that CMR strain results may be influenced by spatial resolution and by the administration of gadolinium-based contrast agent. • The results underline the need for standardized image acquisition for CMR strain analysis, with constant imaging parameters and without contrast agent.
引用
- von Knobelsdorff-Brenkenhoff F, Schunke T, Reiter S, et al. Influence of contrast agent and spatial resolution on myocardial strain results using feature tracking MRI. Eur Radiol. 2020. PMID: 32472273. doi:10.1007/s00330-020-06971-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。