定量冠状动脉造影估测的剪切应力可预测易进展并引发事件的斑块
本研究分析28个5年随访中发生主要不良心血管事件或需血运重建的富脂斑块与119个保持静止的富脂斑块,用三维定量冠状动脉造影重建并模拟血流估测内皮剪切应力。结果显示斑块负荷与最大3 mm剪切应力值为独立预测因子,高剪切应力合并高危解剖特征的病变事件率最高。
要点
- 斑块负荷(HR 1.08)与最大3 mm段剪切应力值(HR 1.11)为MACE-R的独立预测因子。
- 高剪切应力(>4.95 Pa)合并高危解剖(最小管腔面积<4 mm2且斑块负荷>70%)的病变MACE-R率达53.8%。
- 高剪切应力合并低危解剖、低剪切应力合并高危解剖、低剪切应力合并低危解剖的MACE-R率分别为31.6%、20.0%、7.1%(p<0.001)。
核心结论
- 三维定量冠状动脉造影衍生的局部血流动力学变量可提供有用的预后信息,与病变解剖结合能更准确识别MACE-R病变。
研究设计与样本
- 研究分析基线虚拟组织学血管内超声与造影数据,包括28个5年随访中发生MACE-R的富脂斑块和119个保持静止的富脂斑块。
- 基线虚拟组织学血管内超声研究段用三维定量冠状动脉造影软件重建,在所得几何模型中行血流模拟,估测富脂斑块两端压力梯度及3 mm段平均剪切应力值。
关键影像表现/征象
- MACE-R病变较长、最小管腔面积较小、斑块负荷增加、承受更高剪切应力并表现出更高压力梯度。
诊断标准与关键数值
- 多因素分析中斑块负荷为MACE-R独立预测因子(风险比1.08;p=0.004)。
- 多因素分析中最大3 mm段剪切应力值为MACE-R独立预测因子(风险比1.11;p=0.001)。
- 高剪切应力定义为>4.95 Pa,高危解剖定义为最小管腔面积<4 mm2且斑块负荷>70%。
临床应用与阅片要点
- 原文结论认为三维定量冠状动脉造影衍生的局部血流动力学变量与病变解剖结合可更准确识别MACE-R病变。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: This study examined the value of endothelial shear stress (ESS) estimated in 3-dimensional quantitative coronary angiography (3D-QCA) models in detecting plaques that are likely to progress and cause events.
BACKGROUND: Cumulative evidence has shown that plaque characteristics and ESS derived from intravascular ultrasound (IVUS)-based reconstructions enable prediction of lesions that will cause cardiovascular events. However, the prognostic value of ESS estimated by 3D-QCA in nonflow limiting lesions is yet unclear.
METHODS: This study analyzed baseline virtual histology (VH)-IVUS and angiographic data from 28 lipid-rich lesions (i.e., fibroatheromas) that caused major adverse cardiovascular events or required revascularization (MACE-R) at 5-year follow-up and 119 lipid-rich plaques from a control group that remained quiescent. The segments studied by VH-IVUS at baseline were reconstructed using 3D-QCA software. In the obtained geometries, blood flow simulation was performed, and the pressure gradient across the lipid-rich plaque and the mean ESS values in 3-mm segments were estimated. The additive value of these hemodynamic indexes in predicting MACE-R beyond plaque characteristics was examined.
RESULTS: MACE-R lesions were longer, had smaller minimum lumen area, increased plaque burden (PB), were exposed to higher ESS, and exhibited a higher pressure gradient. In multivariable analysis, PB (hazard ratio: 1.08; p = 0.004) and the maximum 3-mm ESS value (hazard ratio: 1.11; p = 0.001) were independent predictors of MACE-R. Lesions exposed to high ESS (>4.95 Pa) with a high-risk anatomy (minimal lumen area <4 mm2 and PB >70%) had a higher MACE-R rate (53.8%) than those with a low-risk anatomy exposed to high ESS (31.6%) or those exposed to low ESS who had high- (20.0%) or low-risk anatomy (7.1%; p < 0.001).
CONCLUSIONS: In the present study, 3D-QCA-derived local hemodynamic variables provided useful prognostic information, and, in combination with lesion anatomy, enabled more accurate identification of MACE-R lesions.
引用
- Bourantas CV, Zanchin T, Torii R, et al. Shear Stress Estimated by Quantitative Coronary Angiography Predicts Plaques Prone to Progress and Cause Events. JACC Cardiovasc Imaging. 2020. PMID: 32417338. doi:10.1016/j.jcmg.2020.02.028
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。