文献速递心血管US

门诊心力衰竭诊所中由护士操作、专家远程医疗判读的远程超声心动图可行性与准确性研究

Feasibility and Accuracy of Tele-Echocardiography, With Examinations by Nurses and Interpretation by an Expert via Telemedicine, in an Outpatient Heart Failure Clinic.
PubMed 文献 · J Ultrasound Med · 2020-05-21

研究纳入门诊心力衰竭诊所连续50例患者,由3名专科护士完成有限超声心动图,经安全传输由院外心内科专家近实时判读,以4名经验丰富的心内科医生超声心动图为参考。左房左室尺寸、容积及功能指标可行性≥94%,与参考测量相关性r=0.75~0.94,完整远程流程平均耗时1.32±0.36小时,结论为可行且可靠。

要点

  • 护士操作的有限超声心动图经院外专家远程判读,左房左室尺寸、容积及功能指标可行性≥94%。
  • 远程判读与参考超声测量的相关性r=0.75~0.94,一致性很高。
  • 从开始超声到护士收到专家报告,完整远程流程平均1.32±0.36小时。

核心结论

  • 门诊心力衰竭诊所中护士完成有限超声心动图并由院外心内科专家远程判读是可行且可靠的。
  • 该模式可能减少地理差异,使更多患者从非心内科医生实施聚焦超声心动图中获益。

研究设计与样本

  • 研究纳入门诊心力衰竭诊所连续50例患者,中位年龄79岁(范围33-95岁),女性占46%。
  • 由3名专科护士之一完成有限超声心动图,经安全传输模型发送至1名院外心内科医生进行近实时判读。
  • 参考方法为1名经验丰富的心内科医生(共4名中之一)完成的超声心动图。

诊断标准与关键数值

  • 远程医疗方式评估和量化左房左室尺寸、容积及功能指标的可行性在94%或以上。
  • 远程医疗方式与参考测量的相关性r=0.75~0.94,一致性很高。
  • 完整远程医疗流程从超声开始至护理人员收到心内科医生报告的平均时间±标准差为1.32±0.36小时(范围1.58小时)。

临床应用与阅片要点

  • 在门诊心力衰竭诊所中,可由专科护士完成有限超声心动图并交由院外专家远程判读,用于诊断和随访。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To study the feasibility and accuracy of focused echocardiography by nurses supported by near-real-time interpretation via telemedicine by an experienced cardiologist.

METHODS: Fifty consecutive patients were included from an outpatient heart failure (HF) clinic. Limited echocardiography was performed by 1 of 3 specialized nurses. The echocardiograms were transferred by a secure transfer model for near-real-time interpretation to 1 out-of-hospital cardiologist, assessing, among others, the left ventricular (LV) internal diameter, end-diastolic volume, ejection fraction, left atrial (LA) indexed end-systolic volume, mitral early inflow velocity (E), the ratio of E to mitral late inflow, and the ratio of E to the mitral annular early diastolic velocity. The reference method was echocardiography by 1 of 4 experienced cardiologists.

RESULTS: The median age of the population (46% women) was 79 (range, 33-95) years. The assessment and quantification of LA and LV dimensions, volumes, and functional indices were feasible in 94% or more via the telemedical approach. The agreement with reference measurements was very high by the telemedical approach. The mean duration ± SD of the complete telemedical approach from the start of echocardiography until the cardiologist's report was received by the caregiving nurse was 1.32 ± 0.36 (range, 1.58) hours. The correlations with reference to the above-specified indices were r = 0.75 to 0.94.

CONCLUSIONS: Limited echocardiography by nurses in an outpatient heart failure clinic, supported by interpretation by an out-of-hospital cardiologist, was feasible and reliable. This may reduce geographic disparities and allow more patients to benefit from the advantages of implementing focused echocardiography by noncardiologists in diagnostics and follow-up.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Hjorth-Hansen AK, Andersen GN, Graven T, et al. Feasibility and Accuracy of Tele-Echocardiography, With Examinations by Nurses and Interpretation by an Expert via Telemedicine, in an Outpatient Heart Failure Clinic. J Ultrasound Med. 2020. PMID: 32436616. doi:10.1002/jum.15341

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。