文献速递胸部CT

利用卷积神经网络测定胸部CT肺结节体积变化以鉴别良恶性

Differentiation of Benign from Malignant Pulmonary Nodules by Using a Convolutional Neural Network to Determine Volume Change at Chest CT.
PubMed 文献 · Radiology · 2020-05-26

回顾性分析2014年1月至2016年12月胸部CT肺结节患者,比较有无卷积神经网络(CNN)的计算机辅助体积测量(CADv)在鉴别良恶性结节中的效能。测试集显示,CNN辅助的每日总体积变化AUC为0.94,高于CNN辅助的倍增时间(AUC 0.67)及无CNN的CADv(每日体积变化AUC 0.69、倍增时间AUC 0.58),差异均有统计学意义。

要点

  • CNN辅助CADv的每日总体积变化鉴别良恶性结节AUC达0.94,优于倍增时间及无CNN方法。
  • 测试集结节平均大小11 mm±5,范围4-29 mm,恶性132个、良性158个。
  • CNN辅助每日体积变化的准确率显著高于无CNN方法及两种方法的倍增时间(P<.001)。

关键影像表现/征象

  • 测试集结节包括实性132个(46%)、部分实性106个(36%)、磨玻璃52个(18%)。

诊断标准与关键数值

  • CNN辅助CADv每日总体积变化鉴别良恶性结节AUC 0.94(95%CI 0.90, 0.96),高于CNN辅助倍增时间AUC 0.67(95%CI 0.60, 0.74),P<.001。
  • CNN辅助CADv每日总体积变化AUC 0.94(95%CI 0.90, 0.96),高于无CNN的CADv每日体积变化AUC 0.69(95%CI 0.62, 0.75),P<.001。
  • CNN辅助CADv每日总体积变化AUC 0.94(95%CI 0.90, 0.96),高于无CNN的CADv倍增时间AUC 0.58(95%CI 0.51, 0.65),P<.001。
  • CNN辅助CADv每日总体积变化的准确率显著高于无CNN方法(P<.001)及两种方法的倍增时间(P<.001)。

临床应用与阅片要点

  • 作者结论认为卷积神经网络有助于提高CT肺结节体积测量计算机辅助检测的准确率及结节鉴别能力。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Deep learning may help to improve computer-aided detection of volume (CADv) measurement of pulmonary nodules at chest CT. Purpose To determine the efficacy of a deep learning method for improving CADv for measuring the solid and ground-glass opacity (GGO) volumes of a nodule, doubling time (DT), and the change in volume at chest CT. Materials and Methods From January 2014 to December 2016, patients with pulmonary nodules at CT were retrospectively reviewed. CADv without and with a convolutional neural network (CNN) automatically determined total nodule volume change per day and DT. Area under the curves (AUCs) on a per-nodule basis and diagnostic accuracy on a per-patient basis were compared among all indexes from CADv with and without CNN for differentiating benign from malignant nodules. Results The CNN training set was 294 nodules in 217 patients, the validation set was 41 nodules in 32 validation patients, and the test set was 290 nodules in 188 patients. A total of 170 patients had 290 nodules (mean size ± standard deviation, 11 mm ± 5; range, 4-29 mm) diagnosed as 132 malignant nodules and 158 benign nodules. There were 132 solid nodules (46%), 106 part-solid nodules (36%), and 52 ground-glass nodules (18%). The test set results showed that the diagnostic performance of the CNN with CADv for total nodule volume change per day was larger than DT of CADv with CNN (AUC, 0.94 [95% confidence interval {CI}: 0.90, 0.96] vs 0.67 [95% CI: 0.60, 0.74]; P < .001) and CADv without CNN (total nodule volume change per day: AUC, 0.69 [95% CI: 0.62, 0.75]; P < .001; DT: AUC, 0.58 [95% CI: 0.51, 0.65]; P < .001). The accuracy of total nodule volume change per day of CADv with CNN was significantly higher than that of CADv without CNN (P < .001) and DT of both methods (P < .001). Conclusion Convolutional neural network is useful for improving accuracy of computer-aided detection of volume measurement and nodule differentiation capability at CT for patients with pulmonary nodules. © RSNA, 2020 Online supplemental material is available for this article.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Ohno Y, Aoyagi K, Yaguchi A, et al. Differentiation of Benign from Malignant Pulmonary Nodules by Using a Convolutional Neural Network to Determine Volume Change at Chest CT. Radiology. 2020. PMID: 32452736. doi:10.1148/radiol.2020191740

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。