文献速递胸部介入CT

CT引导下微弹簧圈定位肺结节用于VATS术前:胸膜标记失败危险因素的回顾性评估

CT-guided microcoil localization for pulmonary nodules before VATS: a retrospective evaluation of risk factors for pleural marking failure.
PubMed 文献 · Eur Radiol · 2020-05-26

回顾性纳入249例患者共279个肺结节,行CT引导下微弹簧圈定位后VATS,术中28个结节未观察到脏层胸膜上微弹簧圈近端。多因素logistic回归显示针-胸膜角度≤30°、胸膜-微弹簧圈距离≤10 mm及10~20 mm、胸膜凹陷征是胸膜标记失败的独立危险因素。作者结论认为该定位方法安全有效。

要点

  • 针-胸膜角度≤30°时胸膜标记失败风险显著增高(OR=39.022,p=0.003)。
  • 胸膜-微弹簧圈距离≤10 mm(OR=87.054)和10~20 mm(OR=10.088)均为失败危险因素。
  • 存在胸膜凹陷征时标记失败风险增高(OR=21.623,p<0.001)。

核心结论

  • CT引导下微弹簧圈定位肺结节是安全有效的方法,但针-胸膜角度≤30°、胸膜-微弹簧圈距离≤20 mm及胸膜凹陷征是胸膜标记失败的显著危险因素。

研究设计与样本

  • 回顾性纳入249例连续患者共279个肺结节,VATS术前行CT引导下微弹簧圈定位,按术中观察分为两组,采用单因素分析和多因素logistic回归筛选与操作结果相关的独立因素。

关键影像表现/征象

  • 279个结节中28个在VATS术中未能观察到脏层胸膜上微弹簧圈近端。

诊断标准与关键数值

  • 针-胸膜角度≤30°:OR=39.022,p=0.003。
  • 胸膜-微弹簧圈距离≤10 mm:OR=87.054,p<0.001;10~20 mm:OR=10.088,p=0.010。
  • 存在胸膜凹陷征:OR=21.623,p<0.001。

临床应用与阅片要点

  • 阅片规划定位路径时关注针-胸膜角度(≤30°为危险因素)及胸膜-微弹簧圈距离(≤20 mm为危险因素)。
  • 术前CT见胸膜凹陷征时提示胸膜标记失败风险增高(OR=21.623,p<0.001)。
  • 术中VATS观察脏层胸膜微弹簧圈近端,原文报告279个结节中28个未观察到近端。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To summarize the experiences of CT-guided microcoil localization before video-assisted thoracoscopic surgery (VATS) and to investigate the risk factors associated with pleural marking failure.

METHODS: Totally, 249 consecutive patients with 279 pulmonary nodules who underwent CT-guided microcoil localization prior to VATS were enrolled in this study. According to intraoperative observation, all the nodules were divided into two groups. The clinical characteristics and microcoil localization procedure-related variables of the nodules were analyzed by univariate analysis and multivariate logistic regression analysis to screen the independent factors associated with procedure results.

RESULTS: Among the 279 nodules, 28 failed to observe the proximal end of the microcoil deployed on visceral pleura during VATS. The logistic regression revealed that needle-pleura angle (≤ 30°: OR = 39.022, p = 0.003), pleura-microcoil distance (≤ 10 mm: OR = 87.054, p < 0.001; 10~20 mm: OR = 10.088, p = 0.010), and presence of pleural indentation (OR = 21.623, p < 0.001) were independent risk factors for pleural marking failure.

CONCLUSIONS: CT-guided microcoil localization for pulmonary nodules is a safe and effective procedure. Small needle-pleura angle (≤ 30°), pleura-microcoil distance (≤ 20 mm), and the presence of pleural indentation during the procedure are significant risk factors contributing to microcoil pleura marking failure.

KEY POINTS: • CT-guided microcoil localization for pulmonary nodules was a safe and effective procedure. • CT-guided microcoil localization for pulmonary nodules yielded low complication rates. • Small needle-pleura angle, short pleura-microcoil distance, and the presence of pleural indentation were contributing to pleura marking failure.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Xu Y, Ma L, Sun H, et al. CT-guided microcoil localization for pulmonary nodules before VATS: a retrospective evaluation of risk factors for pleural marking failure. Eur Radiol. 2020. PMID: 32458172. doi:10.1007/s00330-020-06954-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。