优化CT窗宽设置诊断表现为亚实性结节的腺癌浸润性
回顾性纳入437个亚实性结节并按3:1随机分为训练组327个和测试组110个,在120 kVp图像上以固定窗位35 HU调整窗宽,确定区分浸润性与浸润前病变的最佳窗宽(核心窗宽)为1175 HU。测试组中核心窗设置(WW/WL 1175/35 HU)诊断浸润性的敏感度87.6%、特异度76.2%、准确率85.5%,优于纵隔窗设置(350/35 HU)的49.4%、90.5%、57.3%。
要点
- 在120 kVp图像上,核心窗设置(WW/WL 1175/35 HU)诊断亚实性结节浸润性的准确率为85.5%。
- 纵隔窗设置(350/35 HU)诊断浸润性的敏感度仅49.4%,核心窗设置提高至87.6%。
- 训练组中核心窗宽1175 HU为检测实性成分的最佳截断值,AUC为0.79。
关键影像表现/征象
- 在固定窗位35 HU下调整窗宽,记录实性成分出现或消失时的窗宽。
- 训练组中核心窗宽1175 HU为区分浸润性与浸润前病变的最佳截断值,AUC为0.79。
诊断标准与关键数值
- 437个亚实性结节中,浸润前病变88个(不典型腺瘤样增生17个、原位腺癌71个),浸润性病变349个(微浸润腺癌233个、浸润性腺癌116个)。
- 测试组纵隔窗设置(350/35 HU)诊断浸润性的敏感度49.4%、特异度90.5%、阳性预测值95.7%、阴性预测值29.7%、准确率57.3%。
- 测试组核心窗设置(1175/35 HU)诊断浸润性的敏感度87.6%、特异度76.2%、阳性预测值91.6%、阴性预测值76.2%、准确率85.5%。
临床应用与阅片要点
- 在120 kVp图像上,可考虑使用核心窗设置(WW/WL 1175/35 HU)评估亚实性结节的实性成分以判断浸润性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the optimal window setting to diagnose the invasiveness of lung adenocarcinoma in sub-solid nodules (SSNs).
METHODS: We retrospectively included 437 SSNs and randomly divided them 3:1 into a training group (327) and a testing group (110). The presence of a solid component was regarded as indicator of invasiveness. At fixed window level (WL) of 35 Hounsfield Units (HU), two readers adjusted the window width (WW) in the training group and recorded once a solid component appeared or disappeared on CT images acquired at 120 kVp. The optimal WW cut-off value to differentiate between invasive and pre-invasive lesions, based on the receiver operating characteristic (ROC) curve, was defined as "core" WW. The diagnostic performances of the mediastinal window setting (WW/WL, 350/35 HU) and core window setting were then compared in the testing group.
RESULTS: Of the 437 SSNs, 88 were pre-invasive [17 atypical adenomatous hyperplasia (AAH) and 71 adenocarcinoma in situ (AIS)], 349 were invasive [233 minimally invasive adenocarcinoma (MIA), 116 invasive adenocarcinoma (IA)]. In training group, the core WW of 1175 HU was the optimal cut-off to detect solid components of SSNs (AUC:0.79). In testing group, the sensitivity, specificity, positive, negative predictive value, and diagnostic accuracy for SSN invasiveness were 49.4%, 90.5%, 95.7%, 29.7%, and 57.3% for mediastinal window setting, and 87.6%, 76.2%, 91.6%, 76.2%, and 85.5% for core window setting.
CONCLUSION: At 120 kVp, core window setting (WW/WL, 1175/35 HU) outperformed the traditional mediastinal window setting to diagnose the invasiveness of SSNs.
引用
- Cui X, Fan S, Heuvelmans MA, et al. Optimization of CT windowing for diagnosing invasiveness of adenocarcinoma presenting as sub-solid nodules. Eur J Radiol. 2020. PMID: 32371183. doi:10.1016/j.ejrad.2020.108981
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。