文献速递胸部CT

胸部CT检测COVID-19:诊断准确性的系统综述与Meta分析

Chest CT for detecting COVID-19: a systematic review and meta-analysis of diagnostic accuracy.
PubMed 文献 · Eur Radiol · 2020-05-15

该系统综述与Meta分析纳入16项研究共3186例患者,评估胸部CT检测COVID-19的诊断准确性。合并敏感度为92%(95%CI=86-96%),两项研究报告特异度分别为25%(95%CI=22-30%)和33%(95%CI=23-44%)。武汉地区敏感度极高且接近(97%、96%、99%),武汉以外地区敏感度波动于61%至98%。

要点

  • 胸部CT检测COVID-19合并敏感度92%(95%CI=86-96%),武汉地区敏感度达96%-99%。
  • 特异度低,两项研究分别为25%(95%CI=22-30%)和33%(95%CI=23-44%)。
  • 武汉以外地区敏感度波动大(61%-98%),阅片需结合流行病学背景。

核心结论

  • 胸部CT对检测COVID-19具有高敏感度,尤其在疫情严重地区;但特异度低,在紧急疾病控制背景下可快速、便捷、有效地早期识别可疑病例,可能有助于遏制疫情。

研究设计与样本

  • 系统综述与Meta分析,检索PubMed、Embase、Web of Science和CNKI至2020年3月12日,纳入16项研究共3186例患者,采用QUADAS-2工具评估方法学质量。

诊断标准与关键数值

  • 胸部CT检测COVID-19的合并敏感度为92%(95%CI=86-96%);两项研究报告特异度分别为25%(95%CI=22-30%)和33%(95%CI=23-44%)。

临床应用与阅片要点

  • 在疫情严重地区,胸部CT高敏感度有助于早期识别可疑病例并可能有助于遏制疫情;但特异度低,阅片时需注意假阳性可能。

局限性

  • 所有研究偏倚风险总体为中等;Cochran Q检验(p<0.01)和Higgins I2异质性指数(敏感度96%)显示存在显著异质性;仅两项研究报告了特异度。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The purpose of this article was to perform a systematic review and meta-analysis regarding the diagnostic test accuracy of chest CT for detecting coronavirus disease 2019 (COVID-19).

METHODS: PubMed, Embase, Web of Science, and CNKI were searched up to March 12, 2020. We included studies providing information regarding diagnostic test accuracy of chest CT for COVID-19 detection. The methodological quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Sensitivity and specificity were pooled.

RESULTS: Sixteen studies (n = 3186 patients) were included. The risks of bias in all studies were moderate in general. Pooled sensitivity was 92% (95% CI = 86-96%), and two studies reported specificity (25% [95% CI = 22-30%] and 33% [95% CI = 23-44%], respectively). There was substantial heterogeneity according to Cochran's Q test (p < 0.01) and Higgins I2 heterogeneity index (96% for sensitivity). After dividing the studies into two groups based on the study site, we found that the sensitivity of chest CT was great in Wuhan (the most affected city by the epidemic) and the sensitivity values were very close to each other (97%, 96%, and 99%, respectively). In the regions other than Wuhan, the sensitivity varied from 61 to 98%.

CONCLUSION: Chest CT offers the great sensitivity for detecting COVID-19, especially in a region with severe epidemic situation. However, the specificity is low. In the context of emergency disease control, chest CT provides a fast, convenient, and effective method to early recognize suspicious cases and might contribute to confine epidemic.

KEY POINTS: • Chest CT has a high sensitivity for detecting COVID-19, especially in a region with severe epidemic, which is helpful to early recognize suspicious cases and might contribute to confine epidemic.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Xu B, Xing Y, Peng J, et al. Chest CT for detecting COVID-19: a systematic review and meta-analysis of diagnostic accuracy. Eur Radiol. 2020. PMID: 32415585. doi:10.1007/s00330-020-06934-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。