扩散加权MRI:感兴趣区大小对头颈部鳞状细胞癌亚厘米淋巴结转移检出的影响
前瞻性纳入51例经病理证实的头颈部鳞状细胞癌患者,在ADC图上分别以0.2 cm²中心ROI和全淋巴结ROI测量淋巴结ADC值。较小ROI在检出转移方面较全淋巴结ADC值具有更高的敏感度、特异度、NPV、PPV和AUC(88.0%、80.73%、90.7%、75.9%、0.912% vs 80.0%、77.98%、85%、71.4%、0.819%,P<0.001)。原发肿瘤病理分级与淋巴结ADC值呈负相关。
要点
- 亚厘米淋巴结转移检出中,0.2 cm²中心ROI的ADC值诊断效能优于全淋巴结ROI。
- 原发肿瘤病理分级越高,淋巴结ADC值越低(rho=-0.425,P=0.002)。
- 测量淋巴结ADC时ROI大小会影响ADC值,需在报告中注明测量方式。
关键影像表现/征象
- 亚厘米淋巴结转移检出中,0.2 cm²中心ROI的ADC值敏感度为88.0%、特异度为80.73%、NPV为90.7%、PPV为75.9%、AUC为0.912%。
- 全淋巴结ROI的ADC值敏感度为80.0%、特异度为77.98%、NPV为85%、PPV为71.4%、AUC为0.819%。
- 较小ROI较全淋巴结ROI在检出转移方面具有更高的敏感度、特异度、NPV、PPV和AUC(P<0.001)。
- 原发肿瘤病理分级与淋巴结ADC值在0.2 cm²ROI和全淋巴结ROI均呈统计学显著负相关(rho=-0.425,P=0.002;rho=-0.298,P=0.038)。
诊断标准与关键数值
- 淋巴结ADC值测量:0.2 cm²ROI置于淋巴结中心 vs 全淋巴结ROI。
- 0.2 cm²中心ROI的ADC值检出转移的敏感度88.0%、特异度80.73%、NPV 90.7%、PPV 75.9%、AUC 0.912%。
- 全淋巴结ROI的ADC值检出转移的敏感度80.0%、特异度77.98%、NPV 85%、PPV 71.4%、AUC 0.819%。
临床应用与阅片要点
- 在ADC图上测量淋巴结ADC值时,采用0.2 cm²中心ROI较全淋巴结ROI可提高亚厘米转移淋巴结的检出效能。
- 原发肿瘤病理分级较高时,淋巴结ADC值可能更低,判读时需结合原发肿瘤分级。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Our aim is to determine the impact of the size of ROI in detecting subcentimeter metastatic lymph nodes in patients with head and neck squamous cell carcinoma (HNSCC). Secondary aim is to determine the impact of the histopathologic grade of the primary cancer on the ADC value of the metastatic nodes.
METHODS: The prospective study included 51 patients with histopathologically proven HNSCC at the primary site. Primary site includes oral cavity, oropharynx, larynx, and hypopharynx. ADC values of the lymph nodes were measured on ADC maps by placing two ROIs in the lymph nodes (0.2 cm2 in the center of the node and the whole node). Lymph nodes were dissected by levels, marked by the surgeon, and sent to the pathologist.
RESULTS: By applying a smaller ROI, ADC values have greater sensitivity, specificity, NPV, PPV, and AUC in detecting metastasis compared to the ADC value of the entire node (88.0%, 80.73%, 90.7%, 75.9%, 0.912% versus 80.0%, 77.98%, 85% ,71.4%, and 0.819%, respectively) p < 0.001. Statistically significant negative correlation was established between the tumor grade and the ADC of lymph node at ROI 0.2 cm2and ROI of the whole lymph node (rho = - 0.425; p = 0.002, and rho = - 0.298; p = 0.038, respectively).
CONCLUSION: ROI size affects the ADC value of the nodes. The higher histopathological grade of the primary tumor is inversely correlated with the ADC value of the lymph nodes.
引用
- Jović A, Fila J, Gršić K, et al. Diffusion-weighted MRI: impact of the size of the ROI in detecting metastases in subcentimeter lymph nodes in head and neck squamous cell carcinoma. Neuroradiology. 2020. PMID: 32418025. doi:10.1007/s00234-020-02449-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。