文献速递神经儿科影像MR

弥漫性内生性脑桥胶质瘤的肿瘤反应评估:半自动体积、半自动线性与手动线性测量策略的比较

Tumor Response Assessment in Diffuse Intrinsic Pontine Glioma: Comparison of Semiautomated Volumetric, Semiautomated Linear, and Manual Linear Tumor Measurement Strategies.
PubMed 文献 · AJNR Am J Neuroradiol · 2020-04-30

本研究通过I/II期试验(NCT02607124)评估10例弥漫性内生性脑桥胶质瘤患者(中位年龄7.6岁)的58次MR检查,比较手动2D、半自动2D和体积测量策略。结果显示手动2D交叉乘积可能低估肿瘤大小和疾病进展,而半自动和体积测量的一致性更好。

要点

  • 手动2D交叉乘积与半自动交叉乘积的百分比变化相关性弱(r=0.36)。
  • 稳定疾病率:手动交叉乘积82%,半自动交叉乘积54%,体积50%。
  • 手动2D交叉乘积可能低估肿瘤大小和疾病进展。

诊断标准与关键数值

  • 临床与半自动交叉乘积的肿瘤大小百分比变化:r=0.36,平均偏差-1.5%(95%界限-59.9%, 56.8%)。
  • 临床交叉乘积与体积的肿瘤大小百分比变化:r=0.61,平均偏差-2.1%(95%界限-52.0%, 47.8%)。
  • 半自动交叉乘积与体积的肿瘤大小百分比变化:r=0.79,平均偏差0.6%(95%界限-39.3%, 38.1%)。
  • 稳定疾病、进展疾病和部分缓解率:临床交叉乘积分别为82%、18%、0%;半自动交叉乘积分别为54%、42%、4%;体积分别为50%、46%、4%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: 2D measurements of diffuse intrinsic pontine gliomas are limited by variability, and volumetric response criteria are poorly defined. Semiautomated 2D measurements may improve consistency; however, the impact on tumor response assessments is unknown. The purpose of this study was to compare manual 2D, semiautomated 2D, and volumetric measurement strategies for diffuse intrinsic pontine gliomas.

MATERIALS AND METHODS: This study evaluated patients with diffuse intrinsic pontine gliomas through a Phase I/II trial (NCT02607124). Clinical 2D cross-product values were derived from manual linear measurements (cross-product = long axis × short axis). By means of dedicated software (mint Lesion), tumor margins were traced and maximum cross-product and tumor volume were automatically derived. Correlation and bias between methods were assessed, and response assessment per measurement strategy was reported.

RESULTS: Ten patients (median age, 7.6 years) underwent 58 MR imaging examinations. Correlation and mean bias (95% limits) of percentage change in tumor size from prior examinations were the following: clinical and semiautomated cross-product, r = 0.36, -1.5% (-59.9%, 56.8%); clinical cross-product and volume, r = 0.61, -2.1% (-52.0%, 47.8%); and semiautomated cross-product and volume, r = 0.79, 0.6% (-39.3%, 38.1%). Stable disease, progressive disease, and partial response rates per measurement strategy were the following: clinical cross-product, 82%, 18%, 0%; semiautomated cross-product, 54%, 42%, 4%; and volume, 50%, 46%, 4%, respectively.

CONCLUSIONS: Manual 2D cross-product measurements may underestimate tumor size and disease progression compared with semiautomated 2D and volumetric measurements.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Gilligan LA, DeWire-Schottmiller MD, Fouladi M, et al. Tumor Response Assessment in Diffuse Intrinsic Pontine Glioma: Comparison of Semiautomated Volumetric, Semiautomated Linear, and Manual Linear Tumor Measurement Strategies. AJNR Am J Neuroradiol. 2020. PMID: 32354716. doi:10.3174/ajnr.A6555

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。