文献速递神经MR

在临床扩散张量成像扫描中可视化听辐射的拓扑结构

Visualising the topography of the acoustic radiation in clinical diffusion tensor imaging scans.
PubMed 文献 · Neuroradiology · 2020-05-19

本研究应用单纤维概率分析结合动态规划方法,在正常听力(n=11)和重度听力损失(n=5)受试者的临床1.5 T扩散张量成像扫描中重建听辐射三维模型,并纳入1例正常听力和1例重度听力损失受试者的3 T数据,成功率为100%。相对于MNI坐标,1.5 T队列中纤维束拓扑结构的varifold距离无显著差异。结论认为该方法可在临床1.5 T和3 T扩散张量成像扫描中可视化听辐射,具有在医学和术前应用中的潜力。

要点

  • 单纤维概率分析结合动态规划可在临床1.5 T和3 T扩散张量成像扫描中可视化听辐射,成功率为100%。
  • 听辐射的拓扑特征此前在尸检和多纤维分析中观察到,现可在16名受试者和2个图谱的扩散张量成像扫描中显示。
  • 1.5 T队列中纤维束拓扑结构的varifold距离相对于MNI坐标无显著差异。

关键影像表现/征象

  • 此前在尸检和多纤维分析中观察到的听辐射拓扑特征可在16名受试者和2个图谱的扩散张量成像扫描中可视化,成功率为100%。
  • 相对于MNI坐标,1.5 T队列中纤维束拓扑结构的varifold距离无显著差异。

临床应用与阅片要点

  • 作者认为,动态规划方法具有在医学和术前应用中(如听神经瘤、多发性硬化、丘脑肿瘤、卒中和听力损失等病理)可视化听辐射的潜力。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: It has long been thought that the acoustic radiation (AR) white matter fibre tract from the medial geniculate body of the thalamus to the Heschl's gyrus cannot be reconstructed via single-fibre analysis of clinical diffusion tensor imaging (DTI) scans. A recently developed single-fibre probabilistic method suggests otherwise. The method uses dynamic programming (DP) to compute the most probable paths between two regions of interest. This study aims to observe the ability of single-fibre probabilistic analysis via DP to visualise the AR in clinical DTI scans from legacy pilot cohorts of subjects with normal hearing (NH) and profound hearing loss (HL).

METHODS: Single-fibre probabilistic analysis via DP was applied to reconstruct 3D models of the AR in the two cohorts. DTI and T1 data at 1.5 T for subjects with NH (n = 11) and HL (n = 5), as well as 3 T for NH (n = 1) and HL (n = 1), were used.

RESULTS: The topographical features of AR previously observed in post-mortem and multi-fibre analyses can be visualised in DTI scans of 16 subjects and 2 atlases with a success rate of 100%. Relative to MNI coordinates, there was no significant difference in the varifold distances between the topography of the tracts in the 1.5 T cohort.

CONCLUSION: The AR can be visualised in clinical 1.5 T and 3 T DTI scans using single-fibre probabilistic analysis via DP, hence, the potential for DP to visualise the AR in medical and pre-surgical applications in pathologies such as vestibular schwannoma, multiple sclerosis, thalamic tumours and stroke as well as hearing loss.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Dhir SB, Kutten KS, Li M, et al. Visualising the topography of the acoustic radiation in clinical diffusion tensor imaging scans. Neuroradiology. 2020. PMID: 32430643. doi:10.1007/s00234-020-02436-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。