文献速递神经外周血管USMRPETCT

超声、高分辨率磁共振成像与正电子发射断层扫描/计算机断层扫描在兔颈动脉易损斑块动脉粥样硬化模型中诊断性能的比较

Comparison of the Diagnostic Performances of Ultrasound, High-Resolution Magnetic Resonance Imaging, and Positron Emission Tomography/Computed Tomography in a Rabbit Carotid Vulnerable Plaque Atherosclerosis Model.
PubMed 文献 · J Ultrasound Med · 2020-05-12

研究在12只新西兰兔(对照组4只、实验组8只)中通过左颈总动脉结扎联合12周高脂饮食诱导动脉粥样硬化模型,并行组织病理学确认,随后比较颈动脉超声、高分辨率磁共振成像(HRMRI)与正电子发射断层扫描/计算机断层扫描(PET/CT)的诊断性能。结果显示实验组左颈总动脉可见斑块形成、狭窄、局部高代谢及易损斑块,右颈总动脉仅见少量斑块且无高代谢;超声检出的软斑块与PET/CT检出的易损斑块不同,HRMRI上的不稳定斑块与PET/CT上的高代谢易损斑块一致。结论推荐HRMRI用于卒中患者颈部及颅内血管狭窄和斑块性质的评估。

要点

  • 实验组左颈总动脉超声可见斑块形成,右颈总动脉仅见少量斑块。
  • HRMRI显示实验组左颈总动脉狭窄形成,水平位左颈总动脉见斑块、右颈总动脉无斑块。
  • PET/CT显示实验组左颈总动脉局部高代谢和易损斑块,右颈总动脉无高代谢。

核心结论

  • 推荐高分辨率磁共振成像用于卒中患者颈部及颅内血管狭窄和斑块性质的评估。

研究设计与样本

  • 研究纳入12只新西兰兔,对照组4只、实验组8只,通过左颈总动脉结扎联合12周高脂饮食诱导临床相关动脉粥样硬化模型,并经组织病理学分析确认。
  • 对模型依次行颈动脉超声、高分辨率磁共振成像和正电子发射断层扫描/计算机断层扫描,以评估诊断性能。

关键影像表现/征象

  • 实验组颈动脉超声显示左颈总动脉斑块形成,右颈总动脉少量斑块。
  • 实验组HRMRI显示左颈总动脉狭窄形成;水平位左颈总动脉见斑块,右颈总动脉无斑块。
  • 实验组PET/CT显示左颈总动脉局部高代谢和易损斑块,右颈总动脉无高代谢。
  • 颈动脉超声检出的软斑块与PET/CT检出的易损斑块不同。
  • HRMRI上的不稳定斑块与PET/CT上的高代谢易损斑块一致。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Our study aimed to evaluate the diagnostic performances of 3 routine examination methods for cerebrovascular disease in a rabbit carotid artery atherosclerosis model.

METHODS: A total of 12 New Zealand rabbits were included: 4 in a control group and 8 in an experimental group. A clinically relevant atherosclerosis rabbit model was induced by left common carotid artery ligation and a 12-week high-fat diet. Atherosclerosis was further confirmed by a histopathologic analysis. Then carotid ultrasound (US) imaging, high-resolution magnetic resonance imaging (HRMRI), and positron emission tomography (PET)/computed tomography (CT) were performed on this model to evaluate the diagnostic performances.

RESULTS: Carotid US showed plaque formation in the left common carotid artery and little plaque in the right common carotid artery in the experimental group. In addition, HRMRI showed stenosis formation in the left common carotid artery in the experimental group. At the horizontal level, plaques were found in the left common carotid artery, and no plaques were found in the right common carotid artery in the experimental group. Also, PET/CT showed local hypermetabolism and vulnerable plaques in the left common carotid artery of the experimental group, whereas no hypermetabolism was found in the right common carotid artery of the experimental group. Moreover, the soft plaques detected by carotid US were different from the vulnerable plaques detected by PET/CT. The unstable plaques on HRMRI were the same as the hypermetabolic vulnerable plaques on PET/CT.

CONCLUSIONS: High-resolution MRI is recommended for the evaluation of neck and intracranial vascular stenosis and plaque properties in patients with stroke.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Xu L, Wang R, Liu H, et al. Comparison of the Diagnostic Performances of Ultrasound, High-Resolution Magnetic Resonance Imaging, and Positron Emission Tomography/Computed Tomography in a Rabbit Carotid Vulnerable Plaque Atherosclerosis Model. J Ultrasound Med. 2020. PMID: 32395879. doi:10.1002/jum.15331

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。