应用应变弹性成像与剪切波弹性成像评估假性脑瘤患者的视神经
研究纳入20例特发性颅内压增高(IIH)患者和20例对照,共40例80眼,行视神经超声、应变弹性成像(SE)和剪切波弹性成像(SWE)检查。IIH组以2型和1型弹性应变模式为主,对照组以3型为主,组间弹性应变模式类型差异有统计学意义(p<0.01);SWE模量对照组为10.1±0.28 kPa,IIH组为26.97±1 kPa,组间差异有统计学意义(p<0.01)。作者认为IIH患者视神经可能发生继发于颅内压升高的生物力学改变,SE和SWE可能作为辅助诊断技术用于检测和随访这些改变。
要点
- IIH组视神经SE以2型和1型弹性应变模式为主,对照组以3型为主,组间差异有统计学意义(p<0.01)。
- SWE模量IIH组为26.97±1 kPa,对照组为10.1±0.28 kPa,组间差异有统计学意义(p<0.01)。
- 作者认为SE和SWE可能作为辅助诊断技术用于检测和随访IIH患者视神经的生物力学改变。
核心结论
- IIH患者视神经可能发生继发于颅内压升高的生物力学改变,SE和SWE可能作为辅助诊断技术用于检测和随访这些改变。
研究设计与样本
- 研究纳入40例(20例IIH患者和20例对照组)共80眼,行视神经超声测量、SE和SWE检查。
- SE模式分为三种主要类型和两种亚型;SWE定量测量视神经硬度,以千帕(kPa)表示。
关键影像表现/征象
- IIH组视神经SE以2型和1型弹性应变模式为主,其次为3型模式。
- 对照组视神经SE以3型弹性应变模式最常见,2型弹性应变模式较少见。
诊断标准与关键数值
- SE弹性应变模式组间类型差异有统计学意义(p<0.01)。
- SWE模量对照组为10.1±0.28 kPa,IIH组为26.97±1 kPa,组间差异有统计学意义(p<0.01)。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To evaluate the optic nerve using strain elastography (SE) and shear-wave elastography (SWE) in idiopathic intracranial hypertension (IIH) patients in comparison to participants in the control group.
MATERIALS AND METHODS: Eighty eyes were evaluated in 40 cases consisting of 20 IIH patients and 20 participants in the control group. This study was conducted using SE and SWE in addition optic nerve sonography measurements of participants in the IIH patient group and the control group. SE patterns were categorised using three main types and two subtypes. Quantitative measurements of optic nerve stiffness with SWE were expressed in kilopascals.
RESULTS: In the IIH patient group, type 2 and type 1 elasticity patterns were primarily observed, followed by type 3 patterns. In the control group, type 3 elasticity patterns were most often observed, while type 2 elasticity patterns were seen less frequently. Statistically significance differences in the types of elasticity strain patterns were observed between the groups (p<0.01). Quantitative analysis was also performed, and the SWE moduli were obtained for the control group (10.1±0.28 kPa) and the IIH patient group (26.97±1 kPa). A statistically significant difference in the SWE modulus was found between the groups (p<0.01).
CONCLUSION: Biomechanical changes may have occurred in the optic nerve secondary to increased intracranial pressure in IIH patients. Strain and shear elastography may have potential as assistive diagnostic techniques for the detection and follow-up of these changes.
引用
- Asal N, İnal M, Şahan MH, et al. Assessment of the optic nerve using strain and shear-wave elastography in patients with pseudotumour cerebri. Clin Radiol. 2020. PMID: 32381345. doi:10.1016/j.crad.2020.03.038
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。