文献速递神经CT

急性缺血性卒中自动化ASPECT评分:三种软件工具的比较

Automated ASPECT scoring in acute ischemic stroke: comparison of three software tools.
PubMed 文献 · Neuroradiology · 2020-05-08

回顾性纳入131例大脑中动脉或颈内动脉大血管闭塞并接受血管内治疗的急性缺血性卒中患者,用三种全自动软件(Syngo.via Frontier ASPECT Score Prototype V2、Brainomix e-ASPECTS、RAPID ASPECTS)评估介入前平扫CT的ASPECT评分,并与三位神经放射科医师共识阅片比较。结果显示软件与专家共识阅片之间相关性高(最高为Brainomix r=0.871),ROC曲线下面积相当(Brainomix AUC=0.759、Frontier V2 AUC=0.752、RAPID AUC=0.734)。

要点

  • 三种ASPECT自动评分软件与专家共识阅片的一致性总体令人信服,但仍有提升空间。
  • Brainomix与专家共识阅片相关性最高(r=0.871),其次为Frontier V2(r=0.801)和RAPID(r=0.777)。
  • 三种软件与专家共识阅片的ROC曲线下面积相当(Brainomix 0.759、Frontier V2 0.752、RAPID 0.734)。

诊断标准与关键数值

  • 专家共识阅片ASPECT评分中位数为8(7-10)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Various software applications offer support in the diagnosis of acute ischemic stroke (AIS), yet it remains unclear whether the performance of these tools is comparable to each other. Our study aimed to evaluate three fully automated software applications for Alberta Stroke Program Early CT (ASPECT) scoring (Syngo.via Frontier ASPECT Score Prototype V2, Brainomix e-ASPECTS® and RAPID ASPECTS) in AIS patients.

METHODS: Retrospectively, 131 patients with large vessel occlusion (LVO) of the middle cerebral artery or the internal carotid artery, who underwent endovascular therapy (EVT), were included. Pre-interventional non-enhanced CT (NECT) datasets were assessed in random order using the automated ASPECT software and by three experienced neuroradiologists in consensus. Interclass correlation coefficient (ICC), Bland-Altman, and receiver operating characteristics (ROC) were applied for statistical analysis.

RESULTS: Median ASPECTS of the expert consensus reading was 8 (7-10). Highest correlation was between the expert read and Brainomix (r = 0.871 (0.818, 0.909), p < 0.001). Correlation between expert read and Frontier V2 (r = 0.801 (0.719, 0.859), p < 0.001) and between expert read and RAPID (r = 0.777 (0.568, 0.871), p < 0.001) was high, respectively. There was a high correlation among the software tools (Frontier V2 and Brainomix: r = 0.830 (0.760, 0.880), p < 0.001; Frontier V2 and RAPID: r = 0.847 (0.693, 0.913), p < 0.001; Brainomix and RAPID: r = 0.835 (0.512, 0.923), p < 0.001). An ROC curve analysis revealed comparable accuracy between the applications and expert consensus reading (Brainomix: AUC = 0.759 (0.670-0.848), p < 0.001; Frontier V2: AUC = 0.752 (0.660-0.843), p < 0.001; RAPID: AUC = 0.734 (0.634-0.831), p < 0.001).

CONCLUSION: Overall, there is a convincing yet developable grade of agreement between current ASPECT software evaluation tools and expert evaluation with regard to ASPECT assessment in AIS.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Hoelter P, Muehlen I, Goelitz P, et al. Automated ASPECT scoring in acute ischemic stroke: comparison of three software tools. Neuroradiology. 2020. PMID: 32382795. doi:10.1007/s00234-020-02439-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。