文献速递神经CTUS

颅内狭窄分级:经颅双功能超声与CT血管造影之间的差异

Classification of Intracranial Stenoses: Discrepancies between Transcranial Duplex Sonography and Computed Tomography Angiography.
PubMed 文献 · Ultrasound Med Biol · 2020-05-19

纳入102例经TCCS发现颅内狭窄的卒中患者,比较TCCS与CTA对狭窄位置和分级的一致性。TCCS检出177处狭窄,仅84处(48%)位置经CTA确认;分级一致率分别为<50% 17%、50%-69% 19%、≥70% 77%。作者提出以狭窄后血流改变和/或软脑膜侧支血流作为TCCS诊断≥70%狭窄的新标准,重度狭窄的一致率较高支持该标准。

要点

  • TCCS与CTA在颅内狭窄检出和分级上存在实质性差异,TCCS检出177处狭窄仅84处(48%)位置经CTA确认。
  • 分级一致率随狭窄程度增加而升高:<50%为17%、50%-69%为19%、≥70%为77%。
  • 作者提出的TCCS ≥70%狭窄标准为:尽管流速可变,依据狭窄后血流改变和/或软脑膜侧支血流。

核心结论

  • TCCS与CTA在颅内狭窄的检出和分级上存在实质性差异,重度狭窄(≥70%)的一致率较高,支持作者提出的TCCS诊断标准。

研究设计与样本

  • 研究纳入102例TCCS发现颅内狭窄的卒中患者(年龄70±13岁),入院24小时内完成TCCS与CTA检查,比较两者对狭窄位置和分级的一致性。

关键影像表现/征象

  • TCCS检出177处颅内狭窄,按部位和分级(<50%/50%-69%/≥70%)分布为:大脑中动脉70处(39/19/12)、基底动脉24处(9/11/4)、大脑前动脉21处(14/7/0)、大脑后动脉49处(29/15/5)、椎动脉13处(2/6/5)。
  • CTA确认狭窄位置84/177处(48%),各部位确认率为:大脑中动脉41/70(59%)、基底动脉16/24(67%)、大脑前动脉2/21(10%)、大脑后动脉17/49(35%)、椎动脉8/13(62%)。
  • TCCS与CTA分级一致率分别为<50% 17%、50%-69% 19%、≥70% 77%。

诊断标准与关键数值

  • TCCS诊断<50%/50%-69%狭窄的收缩期峰值流速截断值:大脑中动脉M1段≥155/≥220 cm/s,M2段≥100/≥140 cm/s,大脑前动脉A1段≥120/≥155 cm/s,大脑后动脉P1和P2段≥100/≥145 cm/s,椎动脉V4段≥90/≥120 cm/s,基底动脉≥100/≥140 cm/s。
  • TCCS诊断≥70%狭窄的标准为:尽管流速可变,依据狭窄后血流改变和/或软脑膜侧支血流。

临床应用与阅片要点

  • 作者提出以狭窄后血流改变和/或软脑膜侧支血流作为TCCS诊断≥70%狭窄的标准,重度狭窄的较高一致率支持该标准。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Transcranial color-coded duplex sonography (TCCS) and computed tomography angiography (CTA) are widely used to identify intracranial stenoses (ISs). We assessed concordance of IS grading between TCCS and CTA and proposed new TCCS criteria for severe IS ≥70%. One hundred two stroke patients (70 ± 13 y) with TCCS-identified IS were included. TCCS and CTA were performed within 24 h after admission. TCCS peak systolic velocity cutoffs for <50%/50%-69% stenoses were ≥155/≥220 cm/s (middle cerebral artery [MCA]-M1), ≥100/≥140 cm/s (MCA-M2), ≥120/≥155 cm/s (anterior cerebral artery [ACA]-A1), ≥100/≥145 cm/s (posterior cerebral artery [PCA]-P1 and PCA-P2), ≥90/≥120 cm/s (vertebral artery [VA]-V4) and ≥100/≥140 cm/s (basilar artery [BA]). Criteria for ≥70% stenoses were, despite variable flow velocities, post-stenotic flow alterations and/or leptomeningeal collateral flow. One hundred seventy-seven ISs were detected by TCCS. The number and grade (<50%/50%-69%/≥70%) of ISs were MCA 70 (39/19/12), BA 24 (9/11/4), ACA 21 (14/7/0), PCA 49 (29/15/5) and VA 13 (2/6/5). IS localization was confirmed by CTA in 84 of 177 cases (48%): MCA, 41/70 (59%); BA, 16/24 (67%); ACA 2/21, (10%); PCA, 17/49 (35%); VA, 8/13 (62%). Concordance between TCCS and CTA grading was (<50%/50%-69%/≥70%) 17%/19%/77%. TCCS and CTA exhibited substantial differences in the detection and grading of IS. Higher concordance rates for severe stenosis support our proposed TCCS criteria.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Danyel LA, Hadzibegovic S, Valdueza JM, et al. Classification of Intracranial Stenoses: Discrepancies between Transcranial Duplex Sonography and Computed Tomography Angiography. Ultrasound Med Biol. 2020. PMID: 32439356. doi:10.1016/j.ultrasmedbio.2020.03.016

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。