文献速递神经MR

3T磁敏感加权成像在多发性硬化诊断中的价值

Value of 3T Susceptibility-Weighted Imaging in the Diagnosis of Multiple Sclerosis.
PubMed 文献 · AJNR Am J Neuroradiol · 2020-05-21

本研究纳入112例临床孤立综合征患者和35例多发性硬化模拟病患者,利用3T磁敏感加权成像计算脑病灶中中央静脉和铁环的出现频率,并检验其预测临床孤立综合征转化为多发性硬化的诊断价值。结果显示,≥3个中央静脉和/或≥1个铁环的敏感度和特异度分别为70%和86%,与空间多发证据联合时,其特异度高于目前用于支持多发性硬化诊断的空间多发证据和寡克隆带阳性。

要点

  • 3T磁敏感加权成像上,中央静脉和铁环是多发性硬化病灶的特异性征象。
  • ≥3个中央静脉和/或≥1个铁环预测临床孤立综合征转化为多发性硬化的敏感度70%、特异度86%。
  • 联合空间多发证据时,中央静脉和铁环的特异度高于空间多发证据联合寡克隆带阳性。

关键影像表现/征象

  • 临床孤立综合征患者中央静脉数量中位数为2个(范围0-19),非多发性硬化组中位数为1个(范围0-6)。
  • 转化为多发性硬化的患者中56%有≥1个铁环,而未转化为多发性硬化的患者均无铁环。

诊断标准与关键数值

  • ≥3个中央静脉和/或≥1个铁环预测临床孤立综合征转化为多发性硬化的敏感度为70%,特异度为86%。
  • 与空间多发证据联合时,中央静脉和铁环两种影像标志物的特异度高于目前用于支持多发性硬化诊断的空间多发证据联合寡克隆带阳性。

临床应用与阅片要点

  • 在3T磁敏感加权成像上识别中央静脉和铁环有助于鉴别多发性硬化与非多发性硬化。
  • ≥3个中央静脉和/或≥1个铁环可作为预测临床孤立综合征转化为多发性硬化的影像指标。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Previous studies have suggested that the central vein sign and iron rims are specific features of MS lesions. Using 3T SWI, we aimed to compare the frequency of lesions with central veins and iron rims in patients with clinically isolated syndrome and MS-mimicking disorders and test their diagnostic value in predicting conversion from clinically isolated syndrome to MS.

MATERIALS AND METHODS: For each patient, we calculated the number of brain lesions with central veins and iron rims. We then identified a simple rule involving an absolute number of lesions with central veins and iron rims to predict conversion from clinically isolated syndrome to MS. Additionally, we tested the diagnostic performance of central veins and iron rims when combined with evidence of dissemination in space.

RESULTS: We included 112 patients with clinically isolated syndrome and 35 patients with MS-mimicking conditions. At follow-up, 94 patients with clinically isolated syndrome developed MS according to the 2017 McDonald criteria. Patients with clinically isolated syndrome had a median of 2 central veins (range, 0-19), while the non-MS group had a median of 1 central vein (range, 0-6). Fifty-six percent of patients who developed MS had ≥1 iron rim, and none of the patients without MS had iron rims. The sensitivity and specificity of finding ≥3 central veins and/or ≥1 iron rim were 70% and 86%, respectively. In combination with evidence of dissemination in space, the 2 imaging markers had higher specificity than dissemination in space and positive findings of oligoclonal bands currently used to support the diagnosis of MS.

CONCLUSIONS: A single 3T SWI scan offers valuable diagnostic information, which has the potential to prevent MS misdiagnosis.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Clarke MA, Pareto D, Pessini-Ferreira L, et al. Value of 3T Susceptibility-Weighted Imaging in the Diagnosis of Multiple Sclerosis. AJNR Am J Neuroradiol. 2020. PMID: 32439639. doi:10.3174/ajnr.A6547

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。