文献速递神经MR

3.0 T磁共振扩散张量纤维束示踪定量评估正常颈段脊髓

Quantitative assessment of cervical spinal cord by diffusion tensor tractography in 3.0 T.
PubMed 文献 · Radiol Med · 2020-05-18

回顾性纳入96名健康受试者,在3.0 T MRI上采用多激发EPI序列行扩散张量成像,分别用圆形和平面感兴趣区法测量颈段脊髓的纤维束数量、FA、MD、AD、RD均值。圆形法获得的纤维束数量显著高于平面法;两组中年龄与FA呈正相关、与RD呈负相关,圆形组还见年龄与MD、AD负相关。作者认为结果可能有助于提供参考值及评估退变、创伤或肿瘤累及的脊髓。

要点

  • 正常颈段脊髓DTT定量参考值:圆形与平面ROI法纤维束数量存在显著差异,圆形法更高。
  • 年龄与FA正相关、与RD负相关,圆形组还见与MD、AD负相关。
  • 作者认为该参考值可能有助于评估退变、创伤或肿瘤累及的脊髓。

关键影像表现/征象

  • 圆形法获得的纤维束数量显著高于平面法。
  • 圆形组年龄与平均FA呈中度正相关(r=0.51,P=0.003)。
  • 圆形组年龄与MD呈弱负相关(r=-0.497,P=0.004),与平均AD呈弱负相关(r=-0.443,P=0.011),与平均RD呈中度负相关(r=-0.542,P=0.001)。
  • 平面组年龄与平均FA呈弱正相关(r=0.403,P=0.022),与平均RD呈弱负相关(r=-0.402,P=0.022)。

诊断标准与关键数值

  • 测量指标包括纤维束数量、平均FA、平均MD、平均AD和平均RD(×10⁻³ mm²/s)。
  • 圆形法与平面法为两种感兴趣区勾画方法,圆形法所得纤维束数量显著高于平面法。

临床应用与阅片要点

  • 作者认为正常颈段脊髓DTT定量值可能作为参考值,用于评估和比较退变、创伤或肿瘤累及的脊髓。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: We aimed to evaluate the mean values of diffusion tensor tracking (DTT) of cervical spinal cord in normal subjects by using multi-shot EPI (MS-EPI) sequence in 3.0 Tesla (3.0T) magnetic resonance imaging (MRI).

METHODS: This retrospective study included 96 healthy subjects. DTI with b-values: 0 and 1000 s/mm2 was performed. Cervical spinal cords were quantitatively evaluated with drawing round or plane region of interest on sagittal images. For all subjects, the number of tracts, mean fractional anisotropy (FA), mean diffusivity (MD), mean axial diffusivity (AD) and mean radial diffusivity (RD) (× 10-3 mm2/s) were measured.

RESULTS: The number of tracts obtained from round method was significantly higher than the ones from plane method. In round group, there was a moderate positive correlation between age and mean FA values (r = 0.51, P = 0.003), a weak negative correlation between age and MD values (r = - 0.497, P = 0.004) and between age and mean AD values (r = - 0.443, P = 0.011), a moderate negative correlation between age and mean RD values (r = - 0.542, P = 0.001). In plane group, there was a weak positive correlation between age and mean FA values (r = 0.403, P = 0.022) and a weak negative correlation between age and mean RD values (r = - 0.402, P = 0.022).

CONCLUSION: Our results might be helpful for emphasizing the reference values and also for evaluating and comparing the pathologic spinal cords affected by degeneration, trauma or tumors.

来源:Radiol Med,查看原文。版权归原作者所有。

引用

  1. Turna O, Turna IF. Quantitative assessment of cervical spinal cord by diffusion tensor tractography in 3.0 T. Radiol Med. 2020. PMID: 32424658. doi:10.1007/s11547-020-01224-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。