多参数磁共振成像无创评估胶质瘤分级
回顾性纳入70例经组织病理学确诊的胶质瘤患者,采用常规MRI、动态磁敏感对比增强及多种扩散加权成像信号模型评估分级。rCBV、MK和α分别为各技术中最准确的参数,三者联合预测肿瘤分级的准确率达94.2%。
要点
- rCBV阈值2.240 ml/100 g鉴别胶质瘤高低级别的AUC为0.844、敏感度87.8%、特异度75.9%。
- MK阈值0.471的AUC为0.873、敏感度92.7%、特异度79.3%,α阈值1.064的AUC为0.847、敏感度79.3%、特异度78.0%。
- rCBV、MK与α联合预测分级的准确率94.2%,高于MK与α联合的89.7%及单用α的85.3%。
核心结论
- 动态磁敏感对比增强的rCBV、扩散峰度成像的MK和多b值扩散加权成像的α分别是各技术中最准确的胶质瘤分级参数。
- 多参数MRI可提高胶质瘤分级的准确率。
研究设计与样本
- 回顾性评估70例连续纳入、经组织病理学确诊的胶质瘤患者,采用常规MRI、动态磁敏感对比增强及包括单指数、双指数、拉伸指数和扩散峰度成像的多重扩散加权成像信号模型。
诊断标准与关键数值
- 归一化相对脑血流量(rCBV)鉴别胶质瘤高低级别的最佳阈值2.240 ml/100 g,AUC 0.844,敏感度87.8%,特异度75.9%。
- 平均峰度(MK)最佳阈值0.471,AUC 0.873,敏感度92.7%,特异度79.3%。
- 水分子扩散异质性指数(α)最佳阈值1.064,AUC 0.847,敏感度79.3%,特异度78.0%。
- α单用的诊断准确率85.3%,MK与α联合的准确率89.7%,rCBV、MK与α联合的准确率94.2%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVE: To investigate the performance of multi-parametric magnetic resonance imaging (MRI) for glioma grading.
MATERIALS AND METHODS: Seventy consecutive patients with histopathologically confirmed glioma were retrospectively evaluated by conventional MRI, dynamic susceptibility-weighted contrast-enhanced, multiple diffusion-weighted imaging signal models including mono-exponential, bi-exponential, stretched exponential, and diffusion kurtosis imaging. One-way analysis of variance and independent-samples t test were used to compare the MR parameter values between low and high grades as well as among all grades of glioma. Receiver operating characteristic analysis, Spearman's correlation analysis, and binary logistic regression analysis were used to assess their diagnostic performance.
RESULTS: The diagnostic performance (the optimal thresholds, area under the receiver operating characteristic curve, sensitivity, and specificity) was achieved with normalized relative cerebral blood flow (rCBV) (2.240 ml/100 g, 0.844, 87.8%, and 75.9%, respectively), mean kurtosis (MK) (0.471, 0.873, 92.7%, and 79.3%), and water molecular diffusion heterogeneity index (α) (1.064, 0.847, 79.3% and 78.0%) for glioma grading. There were positive correlations between rCBV and MK and the tumor grades and negative correlations between α and the tumor grades (p < 0.01). The parameter of α yielded a diagnostic accuracy of 85.3%, the combination of MK and α yielded a diagnostic accuracy of 89.7%, while the combination of rCBV, MK, and α were more accurate (94.2%) in predicting tumor grade.
CONCLUSION: The most accurate parameters were rCBV, MK, and α in dynamic susceptibility-weighted contrast, diffusion kurtosis imaging, and Multi-b diffusion-weighted imaging for glioma grading, respectively. Multiparametric MRI can increase the accuracy of glioma grading.
引用
- Zhang L, Yang LQ, Wen L, et al. Noninvasively Evaluating the Grading of Glioma by Multiparametric Magnetic Resonance Imaging. Acad Radiol. 2020. PMID: 32417035. doi:10.1016/j.acra.2020.03.035
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。