指南与共识介入技术与安全CTUSMR

美国放射学会适宜性标准®:感染性积液的放射学管理

ACR Appropriateness Criteria® Radiologic Management of Infected Fluid Collections.
指南 / 共识 · J Am Coll Radiol · 2020-01-01

感染性积液常见且可发生于全身多种临床场景,影像引导下微创管理因并发症率低、成功率高而常优先于侵入性方案。美国放射学会适宜性标准基于文献分析与RAND/UCLA及GRADE方法,由多学科专家组针对特定临床场景评估影像与治疗操作的适宜性,证据不足时以专家意见补充。

要点

  • 感染性积液的影像引导下微创管理因并发症率低、成功率高而常优先于侵入性方案。
  • 确定最佳管理策略时需考虑具体临床场景、解剖因素及既往或正在进行的治疗。
  • 该指南采用RAND/UCLA适宜性方法与GRADE对影像和治疗操作进行适宜性评级。

核心结论

  • 对感染性积液,影像引导下微创管理策略因并发症率低、成功率高而常优先于侵入性方案。
  • 确定最佳管理策略时需考虑具体临床场景、解剖因素及既往或正在进行的治疗。

研究设计与样本

  • 美国放射学会适宜性标准为针对特定临床状况的循证指南,由多学科专家组每年审查。
  • 指南制定与修订包括对同行评议期刊当前医学文献的广泛分析。
  • 采用RAND/UCLA适宜性方法与GRADE对特定临床场景的影像和治疗操作进行适宜性评级。

诊断标准与关键数值

  • 指南制定与修订采用RAND/UCLA适宜性方法与GRADE评级影像和治疗操作的适宜性。
  • 证据缺乏或模棱两可时,专家意见可补充现有证据以推荐影像或治疗。

临床应用与阅片要点

  • 针对感染性积液,影像引导下微创管理策略常优先于侵入性方案。
  • 制定管理策略时需结合具体临床场景、解剖因素及既往或正在进行的治疗。

局限性

  • 证据缺乏或模棱两可时,专家意见可补充现有证据以推荐影像或治疗。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Infected fluid collections are common and occur in a variety of clinical scenarios throughout the body. Minimally invasive image-guided management strategies for infected fluid collections are often preferred over more invasive options, given their low rate of complications and high rates of success. However, specific clinical scenarios, anatomic considerations, and prior or ongoing treatments must be considered when determining the optimal management strategy. As such, several common scenarios relating to infected fluid collections were developed using evidence-based guidelines for management. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment.

来源:J Am Coll Radiol,查看原文。版权归原作者所有。

引用

  1. Weiss CR, Bailey CR, Hohenwalter EJ, et al. ACR Appropriateness Criteria® Radiologic Management of Infected Fluid Collections. J Am Coll Radiol. 2020. PMID: 32370971. doi:10.1016/j.jacr.2020.01.034

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。