指南与共识妇产影像腹部MR

女性盆腔MRI的患者准备与图像质量:推荐建议的再评估

Patient preparation and image quality in female pelvic MRI: recommendations revisited.
指南 / 共识 · Eur Radiol · 2020-04-30

前瞻性两中心研究评估当前女性盆腔MRI患者准备推荐是否仍适用,发现空腹、饱和带及胰高血糖素可减少伪影并改善图像质量,膀胱中度充盈对图像质量无明确影响但影响宫颈-子宫角,月经周期时机不影响子宫分区解剖显示。

要点

  • 空腹、饱和带及抗痉挛药物(胰高血糖素)可减少肠道运动伪影并改善图像质量,推荐用于女性盆腔MRI。
  • 月经周期时机不影响子宫分区解剖的显示,无需据此安排检查时间。
  • 膀胱充盈影响宫颈-子宫角但图像质量无明确差异;中度充盈时膀胱与子宫间脂肪 delineation 最佳。

关键影像表现/征象

  • 膀胱充盈影响宫颈-子宫角(p<0.001),但对图像质量无明确影响(p>0.05)。
  • 膀胱中度充盈时膀胱与子宫间脂肪 delineation 最佳(p=0.0009)。
  • 膀胱满充盈时卵巢移位最明显(p=0.0059)。
  • 月经周期时机不影响子宫分区解剖的显示(p>0.05)。
  • 空腹(p<0.02)和饱和带(p<0.001)对图像质量有正面影响;胰高血糖素与MRI伪影减少相关(p=0.002)。

临床应用与阅片要点

  • 空腹、抗痉挛药物和饱和带可改善MR图像质量,推荐用于女性盆腔MRI。
  • 膀胱充盈不影响健康志愿者的诊断能力,但临床实践中检查膀胱中度充盈的患者可能有助于减少诊断不准确。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To assess whether with recent MR technology current patient preparation literature recommendations for female pelvic MRI are still valid and how they are influencing the position of the female pelvic organs, image quality, and diagnostic confidence.

METHODS: This prospective study was performed in two centres. The effects of bladder filling (empty, moderate, full; n = 26), fasting, saturation band (n = 25), and menstrual cycle (n = 25) were assessed in healthy subjects in centre 1, while the effect of intravenous glucagon application was evaluated in 20 patients with benign conditions in centre 2. Images of the pelvis were acquired using 1.5-T MRI with T2-weighted turbo spin echo imaging in sagittal and (angulated) transaxial planes. The analysis was conducted hierarchically using paired Wilcoxon tests with an alpha significance level of 0.05.

RESULTS: Urinary bladder filling influenced the cervix-to-uterine angle (p < 0.001) but had no clear effect on image quality (p > 0.05). A moderately full bladder provided the best delineation of fat between the bladder and uterus (p = 0.0009). A full bladder resulted in highest ovarian displacement (p = 0.0059). Timing within the menstrual cycle did not influence the depiction of zonal anatomy (p > 0.05). Fasting (p < 0.02) and saturation bands (p < 0.001) had a positive effect on image quality. Glucagon was associated with decreased MRI artefacts (p = 0.002).

CONCLUSION: Fasting, antispasmodic agents, and saturation bands improved MR image quality and are recommended for female pelvic MRI. Urinary bladder filling influenced the cervix-to-uterine angle, but had no clear effect on image quality.

KEY POINTS: • Fasting, saturation band, and glucagon injection significantly reduced bowel movement artefacts. • Depiction of the anatomical details of the uterus was not influenced by the timing of MRI within the menstrual cycle. • Although bladder filling did not impact diagnostic capabilities in healthy volunteers, in clinical practice, it may be useful to examine patients with a moderately full bladder, to reduce diagnostic inaccuracies.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Sheikh-Sarraf M, Nougaret S, Forstner R, et al. Patient preparation and image quality in female pelvic MRI: recommendations revisited. Eur Radiol. 2020. PMID: 32356160. doi:10.1007/s00330-020-06869-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。