文献速递泌尿生殖腹部CT

尿液稀释后分裂团注双能CT尿路造影:泌尿系结石检出与表征的一站式检查

Split bolus dual-energy CT urography after urine dilution: a one-stop shop for detection and characterisation of urolithiasis.
PubMed 文献 · Clin Radiol · 2020-04-25

单中心前瞻性研究纳入130例显微镜血尿成人,行全腹部双能真非增强CT(DETNE)后行分裂团注双能CT尿路造影(SBDECTU),以DETNE为参考标准比较虚拟非增强(VNE)图像的诊断效能。VNE按患者计算敏感度和特异度均为100%,129枚结石中检出118枚(敏感度91.47%),83.9%(99/118)可表征;省略DETNE可节省平均剂量长度乘积537.6±152.9 mGy和容积CT剂量指数10.9±2.9 mGy·cm²。

要点

  • VNE按患者计算检出结石的敏感度和特异度均为100%。
  • 129枚结石中VNE检出118枚,敏感度和准确率均为91.47%。
  • SBDECTU可表征83.9%(99/118)检出的结石。

核心结论

  • SBDECTU在检出和表征临床显著泌尿系结石方面具有高诊断准确率,辐射剂量可能减半。

研究设计与样本

  • 单中心、机构伦理委员会(IEC)批准的前瞻性研究,2014年4月至2015年11月纳入130例签署知情同意的显微镜血尿成人。
  • 所有受试者先行全腹部双能真非增强CT(DETNE),随后行SBDECTU;SBDECTU方案为口服水化和生理盐水注射稀释尿液后同步采集肾图-尿路图。
  • 以DETNE为参考标准,比较SBDECTU衍生的虚拟非增强(VNE)图像对结石的检出和表征,并比较主观图像质量和辐射剂量。

关键影像表现/征象

  • VNE图像上73.1%(19/26)的病例实现完全碘减影。

诊断标准与关键数值

  • VNE按患者计算检出结石的敏感度和特异度均为100%。
  • 129枚结石中VNE检出118枚,敏感度为91.47%,准确率为91.47%。
  • 检出的118枚结石中83.9%(99/118)可在SBDECTU图像上表征。

临床应用与阅片要点

  • SBDECTU可作为检出和表征临床显著泌尿系结石的一站式检查,省略DETNE可节省平均DLP 537.6±152.9 mGy和CTDIvol 10.9±2.9 mGy·cm²。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To determine the diagnostic performance of split-bolus dual-energy computed tomography (CT) urography (SBDECTU) in the detection and characterisation of urolithiasis.

MATERIALS AND METHODS: This single-centre Institute Ethics Committee (IEC)-approved prospective study was conducted from April 2014 to November 2015. One hundred and thirty consenting adults with microscopic haematuria underwent dual-energy true non-enhanced CT (DETNE) of the whole abdomen followed by a SBDECTU. The SBDECTU protocol consisted of synchronous nephrogram-urogram acquisition following urine dilution by oral hydration and normal saline injection. Calculi were detected and characterised using virtual non-enhanced (VNE) images derived from SBDECT were compared with DETNE (the reference standard). The subjective image quality and radiation dose were compared.

RESULTS: Twenty-six participants had one or more calculi (total 129 calculi) detected on DETNE CT. The sensitivity and specificity of VNE on a per-patient basis were 100%. Of the 129 calculi, 118 were detected on VNE, with a sensitivity of 91.47% and an accuracy of 91.47%. Of the calculi, 83.9% (99/118) could be characterised on SBDECTU images. On VNE images, complete iodine subtraction was seen in 73.1% (19/26). By omitting DETNE CT, the mean dose-length product of 537.6±152.9 mGy and volume CT dose index of 10.9±2.9 mGy•cm2 could have been saved.

CONCLUSION: SBDECTU has high diagnostic accuracy in the detection and characterisation of clinically significant urinary calculi at potentially half the radiation dose.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Manoharan D, Sharma S, Das CJ, et al. Split bolus dual-energy CT urography after urine dilution: a one-stop shop for detection and characterisation of urolithiasis. Clin Radiol. 2020. PMID: 32345438. doi:10.1016/j.crad.2020.03.020

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。