文献速递腹部儿科影像技术与安全CT

疑似阑尾炎青少年及年轻成人中2-mSv CT与常规剂量CT的诊断敏感度与特异度:LOCAT数据的亚组事后分析

Diagnostic sensitivity and specificity of 2-mSv CT vs. conventional-dose CT in adolescents and young adults with suspected appendicitis: post hoc subgroup analysis of the LOCAT data.
PubMed 文献 · Eur Radiol · 2020-04-02

该研究基于LOCAT试验的方案符合性分析数据,纳入2013年12月至2016年8月间20家医院的2773例疑似阑尾炎患者(中位年龄28岁)和160名放射科医生,比较2-mSv CT与常规剂量CT诊断阑尾炎的敏感度和特异度在各亚组间是否存在差异。结果显示多数亚组敏感度和特异度差值的95%CI不超过4.0个百分点且包含总体组间微小差异,无显著交互作用,提示2-mSv CT可在多样人群中替代常规剂量CT,但极端体型、高阑尾炎炎症反应评分及阑尾切除术量小的医院等亚组患者数有限,需进一步研究。

要点

  • 2-mSv CT与常规剂量CT诊断阑尾炎的敏感度和特异度差异微小,且在各患者或医院特征亚组中表现一致。
  • 多数亚组敏感度和特异度差值的95%CI不超过4.0个百分点,未发现显著交互作用。
  • 极端体型、高阑尾炎炎症反应评分及阑尾切除术量小的医院等亚组患者数有限,结论需进一步研究确认。

核心结论

  • 2-mSv CT与常规剂量CT诊断阑尾炎的敏感度和特异度无显著亚组异质性,提示2-mSv CT可在多样人群中替代常规剂量CT。
  • 对于极端体型、高阑尾炎炎症反应评分或阑尾切除术量小的医院等患者数有限的亚组,需进一步研究确认。

研究设计与样本

  • 研究为对一项2013年12月至2016年8月开展的试验的方案符合性分析数据的事后亚组分析,纳入2773例患者(中位年龄28岁,四分位距21-35岁)和来自20家医院的160名放射科医生。
  • 亚组按性别、体型、阑尾炎临床风险评分、CT检查时间(工作时段与非工作时段)、CT设备、放射科医生经验、所在机构2-mSv CT既往经验及机构实践量划分。
  • 采用森林图及加性或乘性交互作用检验分析辐射剂量与亚组属性的交互作用;若某亚组患者少于200例,则认为该亚组结果无意义。

诊断标准与关键数值

  • 多数亚组敏感度和特异度差值的95%CI为4.0个百分点或更窄,且包含总体组间微小差异。
  • 敏感度或特异度均无显著交互作用。
  • 极端体型、高阑尾炎炎症反应评分及阑尾切除术量小的医院等亚组被认为患者数不足。

临床应用与阅片要点

  • 作者认为2-mSv CT可在多样人群中替代常规剂量CT。
  • 作者指出,对于极端体型、高阑尾炎炎症反应评分或阑尾切除术量小的医院等亚组,需进一步研究确认2-mSv CT能否替代常规剂量CT。

局限性

  • 极端体型、高阑尾炎炎症反应评分及阑尾切除术量小的医院等亚组患者数有限。
  • 需进一步研究以确认2-mSv CT在这些患者数有限的亚组中能否替代常规剂量CT。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To test whether the difference in sensitivity or specificity between 2-mSv CT and conventional-dose CT (CDCT) for the diagnosis of appendicitis differs across subgroups of adolescents and young adults with suspected appendicitis.

MATERIALS AND METHODS: We used the per-protocol analysis data of a trial conducted between Dec 2013 and Aug 2016, including 2773 patients (median age [interquartile range], 28 [21-35] years) and 160 radiologists from 20 hospitals. We defined subgroups by sex, body size, clinical risk scores for appendicitis, time of CT examination (i.e., working vs. after hours), CT machines, radiologists' experience, previous site experience in 2-mSv CT, and site practice volume. We drew forest plots and tested for additive or multiplicative interaction between radiation dose and subgroup attributes. If any subgroup had fewer than 200 patients, we considered the results from that subgroup not meaningful.

RESULTS: For most subgroups, the 95% CIs for the differences in sensitivity and specificity were 4.0 percentage points or narrower and contained the minute overall between-group differences. There was no significant interaction on sensitivity or specificity. A few subgroups, including those of extreme body sizes, high appendicitis inflammatory response scores, and hospitals with small appendectomy volume, were regarded to have insufficient numbers of patients.

CONCLUSIONS: There was no notable subgroup heterogeneity, which implies that 2-mSv CT can replace CDCT in diverse populations. Further studies are needed for the subgroups for which we had only small data.

KEY POINTS: • The minute difference in sensitivity or specificity between the 2-mSv CT and conventional-dose CT (typically 7 mSv) groups were consistent across various patient or hospital characteristics. • These results indicate that 2-mSv CT can replace conventional-dose CT in diverse populations. • Further studies are needed to confirm whether 2-mSv CT can replace conventional-dose CT in patients of extreme body sizes, high appendicitis inflammatory response scores, or hospitals with small appendectomy volume, as those subgroups in our data included limited numbers of patients.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Ko Y, Lee WJ, Park JH, et al. Diagnostic sensitivity and specificity of 2-mSv CT vs. conventional-dose CT in adolescents and young adults with suspected appendicitis: post hoc subgroup analysis of the LOCAT data. Eur Radiol. 2020. PMID: 32240354. doi:10.1007/s00330-020-06811-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。