在儿童和年轻成人中应用双能量CT降低辐射剂量和对比剂用量
该回顾性研究纳入85例儿童和年轻成人行双源双能量CT(DS-DECT)胸部或腹盆部增强检查,并与66例年龄、性别、部位和体重匹配的单能量CT(SECT)患者比较。结果显示DS-DECT的体型特异性剂量估计值显著低于SECT,对比剂用量较SECT降低19%–22%,且所有患者图像质量均可接受。
要点
- 儿童和年轻成人胸部及腹盆部增强检查中,双源双能量CT的辐射剂量显著低于单能量CT。
- 双源双能量CT的对比剂用量较体重和部位匹配的单能量CT降低19%–22%。
- 双源双能量CT图像质量在所有患者中均可接受。
诊断标准与关键数值
- 胸部双源双能量CT的体型特异性剂量估计值为4.0±2.1 mGy,胸部单能量CT为6.1±4.4 mGy,差异有统计学意义(p=0.003–0.005)。
- 腹盆部双源双能量CT的体型特异性剂量估计值为5.0±5.0 mGy,腹盆部单能量CT为8.3±4.0 mGy,差异有统计学意义(p=0.003–0.005)。
- 双源双能量CT检查的对比剂用量较体重和部位匹配的单能量CT扫描降低19%–22%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE. The purpose of this study was to assess if dual-source dual-energy CT (DS-DECT) can be used with lower radiation doses and contrast material volumes than single-energy CT (SECT) in children and young adults. MATERIALS AND METHODS. This retrospective study included 85 consecutive children and young adults (age range, 1 month old to 19 years old; 81 male, 70 female) who underwent contrast-enhanced DS-DECT of the chest (n = 41) or the abdomen and pelvis (n = 44) on second- or third-generation dual-source CT scanners (Somatom Flash or Force, Siemens Healthineers) for clinically indicated reasons. We included 66 age-, sex-, body region-, and weight-matched patients who underwent SECT on the same scanner. Patients were scanned with either SECT (with automatic exposure control using both CARE kV [Siemens Healthineers] and CARE Dose 4D [Siemens Healthineers]) or DS-DECT (with CARE Dose 4D). Two pediatric radiologists assessed clinical indications, radiologic findings, image quality, and any study limitations (noise or artifacts). Patient demographics (age, sex, weight), scan parameters (tube voltage, tube current-time product, pitch, section thickness), CT dose descriptors (volume CT dose index, dose-length product, size-specific dose estimate [SSDE]), and contrast material volume were recorded. Descriptive statistics, paired t test, and Cohen kappa test were performed. RESULTS. Mean patient ages and weights ± SD in DS-DECT (10 ± 6 years old, 38 ± 23 kg) and SECT (11 ± 7 years old, 43 ± 29 kg) groups were not significantly different (p > 0.05). Respective SSDEs for chest DS-DECT (4.0 ± 2.1 mGy), chest SECT (6.1 ± 4.4 mGy), abdomen-pelvis DS-DECT (5.0 ± 5.0 mGy), and abdomen-pelvis SECT (8.3 ± 4.0 mGy) were significantly different (p = 0.003-0.005). Contrast material volume for DS-DECT examinations was 19-22% lower compared with the weight- and body region-matched scans obtained with SECT. Image quality of DECT was acceptable in all patients. CONCLUSION. In children and young adults, chest and abdomen-pelvis DS-DECT enables substantial radiation dose and contrast volume reductions compared with weight- and region-matched SECT.
引用
- Tabari A, Gee MS, Singh R, et al. Reducing Radiation Dose and Contrast Medium Volume With Application of Dual-Energy CT in Children and Young Adults. AJR Am J Roentgenol. 2020. PMID: 32286868. doi:10.2214/AJR.19.22231
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。